REDUCTION OF GRAPHENE OXIDE AND ITS IMPACT ON THE PERFORMANCE ON A BIOSENSING SYSTEM

"Graphene oxide (GO) has aroused the interest of the scientific community due to its extraordinary properties and potential applications; for example, in biosensors, which are analytical devices that can detect the presence of target molecules with high specificity and sensitivity. Particularly...

Full description

Bibliographic Details
Author: DIANA LORENA MANCERA ZAPATA
Format: master thesis
Status:Published version
Publication Date:2020
Country:México
Institution:Centro de Investigaciones en Óptica
Repository:Repositorio Institucional CIO
Language:English
OAI Identifier:oai:cio.repositorioinstitucional.mx:1002/1187
Online Access:http://cio.repositorioinstitucional.mx/jspui/handle/1002/1187
Access Level:Open access
Keyword:info:eu-repo/classification/Autor/Graphene oxide
info:eu-repo/classification/Autor/FRET
info:eu-repo/classification/Autor/Biosensing
info:eu-repo/classification/Autor/Quenching
info:eu-repo/classification/Autor/Reduced graphene oxide
info:eu-repo/classification/Autor/Assay time
info:eu-repo/classification/cti/7
info:eu-repo/classification/cti/33
info:eu-repo/classification/cti/3399
info:eu-repo/classification/cti/339999
Description
Summary:"Graphene oxide (GO) has aroused the interest of the scientific community due to its extraordinary properties and potential applications; for example, in biosensors, which are analytical devices that can detect the presence of target molecules with high specificity and sensitivity. Particularly, GO has been demonstrated to be an excellent photoluminescence quencher, this property is very useful in the development of biosensing systems based on fluorescence resonance energy transfer (FRET). Additionally, it has been reported that the effect of fluorescence quenching is more efficient when GO is reduced. This effect could be directly used to enhance the analytical performance of a FRET–based biosensing system. In the present thesis, the effects generated in the analytical performance of a biosensing platform due to the reduction of GO in three different samples are reported. This study was divided into several stages, the first one consisted of making GO adhesion tests on the surface of tissue culture treated (TCT) microplates, this in order to know the approximate amount of GO that adheres to the surface after stages of washing with ultrapure water, the results of this stage reveals that around 5% of the concentration of GO used to cover the TCT microplates surface remains on it after the washing stages. This information is relevant to the next stage, because the amount of reducing agent, L-ascorbic acid (L-AA ) will depend on this, since the suggested amounts of L-AA correspond to 1.75 and 3.5 times the concentration of GO (1.75x [GO] and 3.5x [GO]). Once the reduction process was performed on GO, photoluminescence quenching studies were performed, and these studies indicated that, effectively, the reduction process generated changes in quenching values (ratio between final and initial intensity, I0/If) from 0.32 to 0.40, and the photoluminescence quenching saturation time from 32 to 25.68 minutes for GO and rGO respectively."