Magnetic particle-based enzyme assays and immunoassays for microcystins: from colorimetric to electrochemical detection

In this work, magnetic particles (MPs) are used as supports for the immobilization of biorecognition molecules for the detection of microcystins (MCs). In one approach, a recombinant protein phosphatase 1 (PP1) has been conjugated to MPs via coordination chemistry, and MC-LR detection has been based...

Full description

Bibliographic Details
Authors: Reverté, Laia, Garibo, Diana, Flores, Cintia, Diogène, Jorge, Caixach, Josep, Campàs, Mònica
Format: article
Status:Versión aceptada para publicación
Publication Date:2013
Country:España
Institution:Consejo Superior de Investigaciones Científicas (CSIC)
Repository:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/413894
Online Access:http://hdl.handle.net/10261/413894
https://api.elsevier.com/content/abstract/scopus_id/84871752751
Access Level:Open access
Keyword:Magnetic particles (MPs)
LC-MS/MS
http://metadata.un.org/sdg/3
http://metadata.un.org/sdg/9
Ensure healthy lives and promote well-being for all at all ages
Build resilient infrastructure, promote inclusive and sustainable industrialization and foster innovation
Description
Summary:In this work, magnetic particles (MPs) are used as supports for the immobilization of biorecognition molecules for the detection of microcystins (MCs). In one approach, a recombinant protein phosphatase 1 (PP1) has been conjugated to MPs via coordination chemistry, and MC-LR detection has been based on the inhibition of the enzyme activity. In the other approach, a monoclonal antibody (mAb) against MC-LR has been conjugated to protein G-coated MPs, and a direct competitive enzyme-linked immunoparticle assay (ELIPA) has been then performed. Conjugation of biomolecules to MPs has been first checked, and after optimization, MC detection has been performed. The colorimetric PPIA with PP1-MP and the best ELIPA strategy have provided limits of detection (LOD) of 7.4 and 3.9 μg/L of MC-LR, respectively. The electrochemical ELIPA has decreased the LOD to 0.4 μg/L, value below the guideline recommended by the World Health Organisation (WHO). The approaches have been applied to the analysis of a cyanobacterial culture and a natural bloom, and MC equivalent contents have been compared to those obtained by conventional assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Results have demonstrated the viability of the use of MPs as biomolecule immobilization supports in biotechnological tools for MCs monitoring.