Microemulsion electrokinetic chromatography as a suitable tool for lipophilicity determination of acidic, neutral, and basic compounds
In the present work, several MEEKC systems are studied to assess their suitability for lipophilicity determination of acidic, neutral, and basic compounds. Thus, several microemulsion compositions over a wide range of pH values (from 2.0 to 12.0), containing heptane, 1−butanol and different types an...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión aceptada para publicación |
| Fecha de publicación: | 2016 |
| País: | España |
| Institución: | Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| Repositorio: | Recercat. Dipósit de la Recerca de Catalunya |
| OAI Identifier: | oai:recercat.cat:2445/101321 |
| Acceso en línea: | https://hdl.handle.net/2445/101321 |
| Access Level: | acceso abierto |
| Palabra clave: | Electroforesi capil·lar Cromatografia de líquids Lipofília Capillary electrophoresis Liquid chromatography Lipophilicity |
| Sumario: | In the present work, several MEEKC systems are studied to assess their suitability for lipophilicity determination of acidic, neutral, and basic compounds. Thus, several microemulsion compositions over a wide range of pH values (from 2.0 to 12.0), containing heptane, 1−butanol and different types and amounts of surfactant (SDS or sodium cholate: from 1.3 to 3.3%) are characterized using Abraham's solvation model. The addition of acetonitrile (up to 10%) is also studied, since it increases the resolution of the technique for the most lipophilic compounds. The system coefficients obtained are very similar to those of the 1−octanol/water, used as the reference lipophilicity index, allowing simple and linear correlations between the 1−octanol/water partition values (log Po/w) and MEEKC mass distribution ratios (log kMEEKC). Variations in the microemulsion composition (aqueous buffer, surfactant, concentration of ACN) did not significantly affect the similarity of the MEEKC systems to log Po/w partition. |
|---|