A Validated Reversed-Phase HPLC Method for the Determination of Atorvastatin Calcium in Tablets
A Reversed-Phase Liquid Chromatographic (RP-LC) assay method was developed for the quantitative determination of atorvastatin calcium in the presence of its degradation products. The assay involved an isocratic elution of atorvastatin calcium in a LiChroCARTR 250*4 mm HPLC Cartridge LiChrospherR 100...
| Autores: | , , , , , |
|---|---|
| Formato: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2014 |
| País: | Argentina |
| Recursos: | Consejo Nacional de Investigaciones Científicas y Técnicas |
| Repositorio: | CONICET Digital (CONICET) |
| Idioma: | inglés |
| OAI Identifier: | oai:ri.conicet.gov.ar:11336/30538 |
| Acesso em linha: | http://hdl.handle.net/11336/30538 |
| Access Level: | acceso abierto |
| Palavra-chave: | Atorvastatin calcium RP-HPLC Tablets assay https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
| Resumo: | A Reversed-Phase Liquid Chromatographic (RP-LC) assay method was developed for the quantitative determination of atorvastatin calcium in the presence of its degradation products. The assay involved an isocratic elution of atorvastatin calcium in a LiChroCARTR 250*4 mm HPLC Cartridge LiChrospherR 100 RP-18 (5 μm) column using a mobile phase consisting of 0.1% acetic acid solution: acetonitrile (45:55, v/v), pH = 3.8. The flow rate was 0.8 mL/min and the analytes monitored at 246 nm. The assay method was found to be linear from 8.13 to 23.77 μg/mL. All the validation parameters were within the acceptance range. The developed method was successfully applied to estimate the amount of atorvastatin calcium in tablets. |
|---|