Influence of Three Dental Implant Surfaces on Cell Viability and Bone Behavior. An In Vitro and a Histometric Study in a Rabbit Model

The chemical composition and the surface characteristics of dental implants are factors that have a decisive effect on the osseointegration process. The surface characterization at the compositional and topographic level of three dental implants available in the market was performed with different s...

Descripción completa

Detalles Bibliográficos
Autores: Rizo-Gorrita, María, Fernández Asián, Ignacio Rafael, Garcia-de-Frenza, Andreina, Vazquez-Pachon, Celia, Serrera Figallo, María de los Ángeles, Torres-Lagares, Daniel, Gutiérrez Pérez, José Luis
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2020
País:España
Institución:Universidad de Sevilla (US)
Repositorio:idUS. Depósito de Investigación de la Universidad de Sevilla
OAI Identifier:oai:idus.us.es:11441/101987
Acceso en línea:https://hdl.handle.net/11441/101987
https://doi.org/10.3390/app10144790
Access Level:acceso abierto
Palabra clave:Dental implant surfaces
Surface roughness
Titanium
Osseointegration
Bone–implant interface
Descripción
Sumario:The chemical composition and the surface characteristics of dental implants are factors that have a decisive effect on the osseointegration process. The surface characterization at the compositional and topographic level of three dental implants available in the market was performed with different surface treatments: (1) sandblasted and acid etched surface (SLA), (2) hydroxyapatite (HA) and tricalcium phosphate (TCP) blasted surface (HA/TCP), and (3) HA-blasted and non-etching acid washed surface (HA + AW). In addition, an in vitro viability study of MG-63 osteoblast cells was performed with a JC-1 test. To complete the study, an in vivo study was conducted in New Zealand rabbits. The study analyzed the histometric characteristics of the bone formed around the implants at the level of area, volume, bone density, accumulated bone density, and bone–implant contact (BIC). The rabbits were sacrificed at 6 weeks after implants were placed in the tibial metaphysis. No statistically significant differences were observed at the level of cell viability or histometric parameters between the different study groups (p > 0.05). SLA and HA/TCP surfaces were the ones that obtained a higher BIC value. Taking into account the limitations of this study, it can be concluded that the different implant surfaces analyzed favor a good bone response.