ATOMS (Adjustable Transobturator Male System) is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an adVance/ adVance XP fixed male sling? a multicenter cohort analysis

This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success...

Descripción completa

Detalles Bibliográficos
Autores: Queisser, Fabian, Rourke, Keith, Schönburg, Sandra, Giammò, Alessandro, Gonsior, Andreas, González Enguita, María del Carmen, Romero, Antonio, Schrader, Andres J., Cruz, Francisco, Martins, Francisco E., Dorado, Juan F., Angulo, Javier C.
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universidad Autónoma de Madrid
Repositorio:Biblos-e Archivo. Repositorio Institucional de la UAM
Idioma:inglés
OAI Identifier:oai:repositorio.uam.es:10486/707560
Acceso en línea:http://hdl.handle.net/10486/707560
https://dx.doi.org/10.3390/jcm11010081
Access Level:acceso abierto
Palabra clave:adjustable transobturator male system
stress urinary incontinence
artificial urinary sphincter
fixed male sling
sling failure
Medicina
Descripción
Sumario:This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0–1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher’s exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien–Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a “very much better” PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up