ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.

Stent underexpansion is a significant challenge in percutaneous coronary intervention, critically impacting patient outcomes. While excimer laser coronary angioplasty (ELCA) and intravascular lithotripsy (IVL) are increasingly used to address this issue, their full impact on the integrity of drug-el...

Descripción completa

Detalles Bibliográficos
Autores: Rivero-Santana, Borja, Galán, Carlos, Pérez-Martínez, Claudia, Ibañez, Borja, Pérez de Prado, Armando, Fernández-Velasco, María, Moreno, Raúl, Jurado-Roman, Alfonso
Tipo de recurso: artículo
Fecha de publicación:2024
País:España
Institución:Instituto de Salud Carlos III (ISCIII)
Repositorio:Repisalud
Idioma:inglés
OAI Identifier:oai:repisalud.isciii.es:20.500.12105/27062
Acceso en línea:https://hdl.handle.net/20.500.12105/27062
Access Level:acceso abierto
Palabra clave:coronary artery disease
drug-eluting stents
lithotripsy
microscopy, electron, scanning
percutaneous coronary intervention
id ES_dff02802ebfe0f493604c9954afeb941
oai_identifier_str oai:repisalud.isciii.es:20.500.12105/27062
network_acronym_str ES
network_name_str España
repository_id_str
spelling ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.Rivero-Santana, BorjaGalán, CarlosPérez-Martínez, ClaudiaIbañez, BorjaPérez de Prado, ArmandoFernández-Velasco, MaríaMoreno, RaúlJurado-Roman, Alfonsocoronary artery diseasedrug-eluting stentslithotripsymicroscopy, electron, scanningpercutaneous coronary interventionStent underexpansion is a significant challenge in percutaneous coronary intervention, critically impacting patient outcomes. While excimer laser coronary angioplasty (ELCA) and intravascular lithotripsy (IVL) are increasingly used to address this issue, their full impact on the integrity of drug-eluting stents remains unclear, raising concerns about their safety and efficacy. This in vitro study assessed the effects of ELCA and IVL on the structural integrity of drug-eluting stents using scanning electron microscopy. Nine stents, 5 Onyx Frontier (with durable circumferential polymer coating) and 4 Cre8 (polymer-free), were implanted in a 3-dimensional coronary artery simulator following standardized protocols. After implantation, treatments with saline-ELCA, contrast-ELCA, IVL, and high-pressure balloon dilatation were applied. A comprehensive evaluation of the stent surface was performed at 60-fold magnification. Scanning electron microscopy analysis revealed significant differences in polymer damage between the techniques. High-pressure balloon dilatation and contrast-ELCA exhibited substantial polymer fragmentation and detachment compared with IVL, saline-ELCA, and conventional dilatation. High-pressure balloon dilatation demonstrated the highest incidence of polymer shaving and overcoating. No significant alterations were observed in polymer-free stents, regardless of the technique used. IVL and saline-ELCA applied immediately after stent implantation produce minimal polymer damage, whereas high-pressure balloon dilatation and contrast-ELCA cause significant damage to the polymer coating. The integrity of polymer-free drug-eluting stent appears stable regardless of the technique used. Further research is needed to validate these findings and explore their clinical implications.LIPPINCOTT WILLIAMS & WILKINS20252025-12-1620242024-11-0120242024-11-01research articlehttp://purl.org/coar/resource_type/c_2df8fbb1VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.12105/27062reponame:Repisaludinstname:Instituto de Salud Carlos III (ISCIII)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:repisalud.isciii.es:20.500.12105/270622026-06-12T12:43:37Z
dc.title.none.fl_str_mv ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
title ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
spellingShingle ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
Rivero-Santana, Borja
coronary artery disease
drug-eluting stents
lithotripsy
microscopy, electron, scanning
percutaneous coronary intervention
title_short ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
title_full ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
title_fullStr ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
title_full_unstemmed ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
title_sort ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy.
dc.creator.none.fl_str_mv Rivero-Santana, Borja
Galán, Carlos
Pérez-Martínez, Claudia
Ibañez, Borja
Pérez de Prado, Armando
Fernández-Velasco, María
Moreno, Raúl
Jurado-Roman, Alfonso
author Rivero-Santana, Borja
author_facet Rivero-Santana, Borja
Galán, Carlos
Pérez-Martínez, Claudia
Ibañez, Borja
Pérez de Prado, Armando
Fernández-Velasco, María
Moreno, Raúl
Jurado-Roman, Alfonso
author_role author
author2 Galán, Carlos
Pérez-Martínez, Claudia
Ibañez, Borja
Pérez de Prado, Armando
Fernández-Velasco, María
Moreno, Raúl
Jurado-Roman, Alfonso
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv
dc.subject.none.fl_str_mv coronary artery disease
drug-eluting stents
lithotripsy
microscopy, electron, scanning
percutaneous coronary intervention
topic coronary artery disease
drug-eluting stents
lithotripsy
microscopy, electron, scanning
percutaneous coronary intervention
description Stent underexpansion is a significant challenge in percutaneous coronary intervention, critically impacting patient outcomes. While excimer laser coronary angioplasty (ELCA) and intravascular lithotripsy (IVL) are increasingly used to address this issue, their full impact on the integrity of drug-eluting stents remains unclear, raising concerns about their safety and efficacy. This in vitro study assessed the effects of ELCA and IVL on the structural integrity of drug-eluting stents using scanning electron microscopy. Nine stents, 5 Onyx Frontier (with durable circumferential polymer coating) and 4 Cre8 (polymer-free), were implanted in a 3-dimensional coronary artery simulator following standardized protocols. After implantation, treatments with saline-ELCA, contrast-ELCA, IVL, and high-pressure balloon dilatation were applied. A comprehensive evaluation of the stent surface was performed at 60-fold magnification. Scanning electron microscopy analysis revealed significant differences in polymer damage between the techniques. High-pressure balloon dilatation and contrast-ELCA exhibited substantial polymer fragmentation and detachment compared with IVL, saline-ELCA, and conventional dilatation. High-pressure balloon dilatation demonstrated the highest incidence of polymer shaving and overcoating. No significant alterations were observed in polymer-free stents, regardless of the technique used. IVL and saline-ELCA applied immediately after stent implantation produce minimal polymer damage, whereas high-pressure balloon dilatation and contrast-ELCA cause significant damage to the polymer coating. The integrity of polymer-free drug-eluting stent appears stable regardless of the technique used. Further research is needed to validate these findings and explore their clinical implications.
publishDate 2024
dc.date.none.fl_str_mv 2024
2024-11-01
2024
2024-11-01
2025
2025-12-16
dc.type.none.fl_str_mv research article
http://purl.org/coar/resource_type/c_2df8fbb1
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.12105/27062
url https://hdl.handle.net/20.500.12105/27062
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv LIPPINCOTT WILLIAMS & WILKINS
publisher.none.fl_str_mv LIPPINCOTT WILLIAMS & WILKINS
dc.source.none.fl_str_mv reponame:Repisalud
instname:Instituto de Salud Carlos III (ISCIII)
instname_str Instituto de Salud Carlos III (ISCIII)
reponame_str Repisalud
collection Repisalud
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869422109023797248
score 15,812429