Amphilimus- vs. zotarolimus-eluting stents in patients with diabetes mellitus and coronary artery disease: the SUGAR trial.
AIM: Patients with diabetes mellitus are at high risk of adverse events after percutaneous revascularization, with no differences in outcomes between most contemporary drug-eluting stents. The Cre8 EVO stent releases a formulation of sirolimus with an amphiphilic carrier from laser-dug wells, and ha...
| Autores: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | INCLIVA |
| Repositorio: | r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA |
| OAI Identifier: | oai:incliva.fundanetsuite.com:p16511 |
| Acceso en línea: | https://incliva.portalinvestigacion.com/publicaciones/16511 |
| Access Level: | acceso abierto |
| Palabra clave: | Diabetes mellitus Drug-eluting stents Percutaneous coronary intervention Randomized trial |
| Sumario: | AIM: Patients with diabetes mellitus are at high risk of adverse events after percutaneous revascularization, with no differences in outcomes between most contemporary drug-eluting stents. The Cre8 EVO stent releases a formulation of sirolimus with an amphiphilic carrier from laser-dug wells, and has shown clinical benefits in diabetes. We aimed to compare Cre8 EVO stents to Resolute Onyx stents (a contemporary polymer-based zotarolimus-eluting stent) in patients with diabetes. METHODS AND RESULTS: We did an investigator-initiated, randomized, controlled, assessor-blinded trial at 23 sites in Spain. Eligible patients had diabetes and required percutaneous coronary intervention. A total of 1175 patients were randomly assigned (1:1) to receive Cre8 EVO or Resolute Onyx stents. The primary endpoint was target-lesion failure, defined as a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target-lesion revascularization at 1-year follow-up. The trial had a non-inferiority design with a 4% margin for the primary endpoint. A superiority analysis was planned if non-inferiority was confirmed. There were 106 primary events, 42 (7.2%) in the Cre8 EVO group and 64 (10.9%) in the Resolute Onyx group [hazard ratio (HR): 0.65, 95% confidence interval (CI): 0.44-0.96; Pnon-inferiority < 0.001; Psuperiority = 0.030]. Among the secondary endpoints, Cre8 EVO stents had significantly lower rate than Resolute Onyx stents of target-vessel failure (7.5% vs. 11.1%, HR: 0.67, 95% CI: 0.46-0.99; P = 0.042). Probable or definite stent thrombosis and all-cause death were not significantly different between groups. CONCLUSION: In patients with diabetes, Cre8 EVO stents were non-inferior to Resolute Onyx stents with regard to target-lesion failure composite outcome. An exploratory analysis for superiority at 1 year suggests that the Cre8 EVO stents might be superior to Resolute Onyx stents with regard to the same outcome. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov: NCT03321032. |
|---|