Clinical tool to measure fluorescein patterns in orthokeratology
Background: Orthokeratology (ortho-k) is an overnight clinical contact lens wear technique to correct myopia and to reduce myopia progression wearing reverse-geometry rigid gas-permeable lenses. The lens fitting procedure in clinical practice usually requires subjective assessment of fluorescein pat...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universidad de Valladolid |
| Repositorio: | UVaDOC. Repositorio Documental de la Universidad de Valladolid |
| OAI Identifier: | oai:uvadoc.uva.es:10324/81035 |
| Acceso en línea: | https://doi.org/10.7717/peerj.14068 https://uvadoc.uva.es/handle/10324/81035 |
| Access Level: | acceso abierto |
| Palabra clave: | Optometria 2209.15 Optometría |
| Sumario: | Background: Orthokeratology (ortho-k) is an overnight clinical contact lens wear technique to correct myopia and to reduce myopia progression wearing reverse-geometry rigid gas-permeable lenses. The lens fitting procedure in clinical practice usually requires subjective assessment of fluorescein pattern (fluorescein "bull's eye" pattern). The aim of this study was to develop a novel tool for fluorescein pattern measurements to reduce subjective practitioner dependency, especially in inexperienced practitioners, in ortho-k practice. Methods: A new MATLAB customized algorithm to measure the horizontal width of the four main zones of ortho-k fluorescein patterns (central bearing, tear reservoir, mid-peripheral bearing and edge lift) was designed. The algorithm was tested on a small image database consisting of 26 ortho-k fluorescein pattern images of 13 volunteers fitted with reverse geometry lenses (Seefree, Conoptica-Hecht Contactlinsen). The agreement between two independent observers and the ImageJ measurements was determined. Results: The new clinical tool provided similar measurements to ImageJ software for the central bearing (4.20 ± 0.74 and 4.27 ± 0.69 mm; P = 0.21), tear reservoir (1.69 ± 0.41 and 1.69 ± 0.45 mm; P = 0.69), mid-peripheral bearing (1.17 ± 0.11 and 1.13 ± 0.10 mm; P < 0.01) and edge lift (0.48 ± 0.06 and 0.48 ± 0.06 mm; P = 0.81) zones. Good agreement between the software (limits of agreement lower than ±0.55 mm) and inter-observer measurements (limits of agreement lower than ±0.66 mm) was found. Conclusions: The proposed clinical tool for semiautomatic fluorescein pattern measurements in ortho-k could help to reduce practitioner dependency in fluorescein pattern assessment with future potential to introduce prediction algorithms or artificial intelligence methods in myopia control management. |
|---|