4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes
This work shows the potential of modified screen-printed carbon electrodes (SPCEs) for sensitive and selective detection of 4-ethylphenol in wine. Gold nanoparticles (AuNPs) and fullerene C60 (C60), modified sensors have been compared. pH of the supporting electrolyte, deposition time and working te...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2022 |
| País: | España |
| Recursos: | Universidad de Burgos (UBU) |
| Repositorio: | Repositorio Institucional de la Universidad de Burgos (RIUBU) |
| OAI Identifier: | oai:riubu.ubu.es:10259/7493 |
| Acesso em linha: | http://hdl.handle.net/10259/7493 |
| Access Level: | acceso abierto |
| Palavra-chave: | 4-ethylphenol Screen-printed electrodes Fullerene Gold nanoparticles Wine Química analítica Chemistry, Analytic |
| id |
ES_ce7ca333adba1aa06c8ddc0efb0072ff |
|---|---|
| oai_identifier_str |
oai:riubu.ubu.es:10259/7493 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodesPortugal Gómez, PaulaAlonso Lomillo, Mª AsunciónDomínguez Renedo, Olga4-ethylphenolScreen-printed electrodesFullereneGold nanoparticlesWineQuímica analíticaChemistry, AnalyticThis work shows the potential of modified screen-printed carbon electrodes (SPCEs) for sensitive and selective detection of 4-ethylphenol in wine. Gold nanoparticles (AuNPs) and fullerene C60 (C60), modified sensors have been compared. pH of the supporting electrolyte, deposition time and working temperature have been optimized considering their influence in the voltammetric pulse response of 4-ethylphenol. Under the optimal conditions of measurement, the developed activated C60/SPCE (AC60/SPCE) shows the best performance, with a detection capability of 400 μg/L and 700 μg/L, when using deposition times of 14 min and 6 min, respectively (α = β = 0.05). The reproducibility of the developed sensor resulted better when a deposition time of 6 min was used (5.4 %, n = 3). The influence of different interferents on the analytical response has been studied, as well as their application in the determination of 4-ethylphenol in different wine samples.Authors would like to acknowledge funding obtained by Junta de Castilla y León (BU018G19) and Agencia Estatal de Investigación (PID2020-117095RB-I00).Elsevier202320232022info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10259/7493reponame:Repositorio Institucional de la Universidad de Burgos (RIUBU)instname:Universidad de Burgos (UBU)InglésMicrochemical Journal. 2022, V. 180, 107599https://doi.org/10.1016/j.microc.2022.107599info:eu-repo/grantAgreement/Junta de Castilla y León//BU018G19info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-117095RB-I00Attribution-NonCommercial-NoDerivatives 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:riubu.ubu.es:10259/74932026-05-28T07:56:11Z |
| dc.title.none.fl_str_mv |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| title |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| spellingShingle |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes Portugal Gómez, Paula 4-ethylphenol Screen-printed electrodes Fullerene Gold nanoparticles Wine Química analítica Chemistry, Analytic |
| title_short |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| title_full |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| title_fullStr |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| title_full_unstemmed |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| title_sort |
4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes |
| dc.creator.none.fl_str_mv |
Portugal Gómez, Paula Alonso Lomillo, Mª Asunción Domínguez Renedo, Olga |
| author |
Portugal Gómez, Paula |
| author_facet |
Portugal Gómez, Paula Alonso Lomillo, Mª Asunción Domínguez Renedo, Olga |
| author_role |
author |
| author2 |
Alonso Lomillo, Mª Asunción Domínguez Renedo, Olga |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
4-ethylphenol Screen-printed electrodes Fullerene Gold nanoparticles Wine Química analítica Chemistry, Analytic |
| topic |
4-ethylphenol Screen-printed electrodes Fullerene Gold nanoparticles Wine Química analítica Chemistry, Analytic |
| description |
This work shows the potential of modified screen-printed carbon electrodes (SPCEs) for sensitive and selective detection of 4-ethylphenol in wine. Gold nanoparticles (AuNPs) and fullerene C60 (C60), modified sensors have been compared. pH of the supporting electrolyte, deposition time and working temperature have been optimized considering their influence in the voltammetric pulse response of 4-ethylphenol. Under the optimal conditions of measurement, the developed activated C60/SPCE (AC60/SPCE) shows the best performance, with a detection capability of 400 μg/L and 700 μg/L, when using deposition times of 14 min and 6 min, respectively (α = β = 0.05). The reproducibility of the developed sensor resulted better when a deposition time of 6 min was used (5.4 %, n = 3). The influence of different interferents on the analytical response has been studied, as well as their application in the determination of 4-ethylphenol in different wine samples. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2023 2023 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10259/7493 |
| url |
http://hdl.handle.net/10259/7493 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Microchemical Journal. 2022, V. 180, 107599 https://doi.org/10.1016/j.microc.2022.107599 info:eu-repo/grantAgreement/Junta de Castilla y León//BU018G19 info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-117095RB-I00 |
| dc.rights.none.fl_str_mv |
Attribution-NonCommercial-NoDerivatives 4.0 Internacional http://creativecommons.org/licenses/by-nc-nd/4.0/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Attribution-NonCommercial-NoDerivatives 4.0 Internacional http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:Repositorio Institucional de la Universidad de Burgos (RIUBU) instname:Universidad de Burgos (UBU) |
| instname_str |
Universidad de Burgos (UBU) |
| reponame_str |
Repositorio Institucional de la Universidad de Burgos (RIUBU) |
| collection |
Repositorio Institucional de la Universidad de Burgos (RIUBU) |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869419995614674944 |
| score |
15,300719 |