A comparison of standardized calculation methods for in situ measurements of facades U-value
In recent years, a growing concern has been how to determine the actual thermal behaviour of façades in their operational stage, in order to establish appropriate energy-saving measures. This paper aims at comparing standardized methods for obtaining the actual thermal transmittance of existing buil...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2016 |
| País: | España |
| Recursos: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/132231 |
| Acesso em linha: | https://hdl.handle.net/2117/132231 https://dx.doi.org/10.1016/j.enbuild.2016.08.072 |
| Access Level: | acceso abierto |
| Palavra-chave: | Insulation (Heat) Facades U-value calculation Thermal transmittance Average method Dynamic method In-situ measurements Facade Aïllament tèrmic Façanes Àrees temàtiques de la UPC::Edificació::Instal·lacions i acondicionament d'edificis::Aïllament acústic i tèrmic |
| id |
ES_c5cd020607c9183d963d40a030bb5404 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/132231 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
A comparison of standardized calculation methods for in situ measurements of facades U-valueGaspar Fàbregas, Kàtia|||0000-0003-3842-1401Casals Casanova, Miquel|||0000-0001-5379-894XGangolells Solanellas, Marta|||0000-0001-7921-595XInsulation (Heat)FacadesU-value calculationThermal transmittanceAverage methodDynamic methodIn-situ measurementsFacadeAïllament tèrmicFaçanesÀrees temàtiques de la UPC::Edificació::Instal·lacions i acondicionament d'edificis::Aïllament acústic i tèrmicIn recent years, a growing concern has been how to determine the actual thermal behaviour of façades in their operational stage, in order to establish appropriate energy-saving measures. This paper aims at comparing standardized methods for obtaining the actual thermal transmittance of existing buildings’ façades, specifically the average method and the dynamic method defined by ISO 9869-1:2014, to verify which best fits theoretical values. The paper also aims to promote the use of the dynamic method, and facilitate its implementation. Differences between the theoretical U-value and the measured U-value obtained using the average and dynamic methods were calculated in three case studies, and then compared. The results showed that differences between the theoretical and the measured U-value were lower when the dynamic method was used. Particularly, when testing conditions were not optimal, the use of the dynamic method significantly improved the fit with the theoretical value. Moreover, measurements of the U-value using the dynamic method with a sufficiently large dataset showed a better fit to the theoretical U-value than the results of other dynamic methods proposed by authors. Further research should consider the optimum size of the dataset to obtain a measured U-value that is correctly adjusted to the theoretical U-value.Peer Reviewed20162016-10-1520192019-04-29journal articlehttp://purl.org/coar/resource_type/c_6501AOhttp://purl.org/coar/version/c_b1a7d7d4d402bcceinfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/132231https://dx.doi.org/10.1016/j.enbuild.2016.08.072reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivs 3.0 Spainhttp://creativecommons.org/licenses/by-nc-nd/3.0/es/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/1322312026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| title |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| spellingShingle |
A comparison of standardized calculation methods for in situ measurements of facades U-value Gaspar Fàbregas, Kàtia|||0000-0003-3842-1401 Insulation (Heat) Facades U-value calculation Thermal transmittance Average method Dynamic method In-situ measurements Facade Aïllament tèrmic Façanes Àrees temàtiques de la UPC::Edificació::Instal·lacions i acondicionament d'edificis::Aïllament acústic i tèrmic |
| title_short |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| title_full |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| title_fullStr |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| title_full_unstemmed |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| title_sort |
A comparison of standardized calculation methods for in situ measurements of facades U-value |
| dc.creator.none.fl_str_mv |
Gaspar Fàbregas, Kàtia|||0000-0003-3842-1401 Casals Casanova, Miquel|||0000-0001-5379-894X Gangolells Solanellas, Marta|||0000-0001-7921-595X |
| author |
Gaspar Fàbregas, Kàtia|||0000-0003-3842-1401 |
| author_facet |
Gaspar Fàbregas, Kàtia|||0000-0003-3842-1401 Casals Casanova, Miquel|||0000-0001-5379-894X Gangolells Solanellas, Marta|||0000-0001-7921-595X |
| author_role |
author |
| author2 |
Casals Casanova, Miquel|||0000-0001-5379-894X Gangolells Solanellas, Marta|||0000-0001-7921-595X |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Insulation (Heat) Facades U-value calculation Thermal transmittance Average method Dynamic method In-situ measurements Facade Aïllament tèrmic Façanes Àrees temàtiques de la UPC::Edificació::Instal·lacions i acondicionament d'edificis::Aïllament acústic i tèrmic |
| topic |
Insulation (Heat) Facades U-value calculation Thermal transmittance Average method Dynamic method In-situ measurements Facade Aïllament tèrmic Façanes Àrees temàtiques de la UPC::Edificació::Instal·lacions i acondicionament d'edificis::Aïllament acústic i tèrmic |
| description |
In recent years, a growing concern has been how to determine the actual thermal behaviour of façades in their operational stage, in order to establish appropriate energy-saving measures. This paper aims at comparing standardized methods for obtaining the actual thermal transmittance of existing buildings’ façades, specifically the average method and the dynamic method defined by ISO 9869-1:2014, to verify which best fits theoretical values. The paper also aims to promote the use of the dynamic method, and facilitate its implementation. Differences between the theoretical U-value and the measured U-value obtained using the average and dynamic methods were calculated in three case studies, and then compared. The results showed that differences between the theoretical and the measured U-value were lower when the dynamic method was used. Particularly, when testing conditions were not optimal, the use of the dynamic method significantly improved the fit with the theoretical value. Moreover, measurements of the U-value using the dynamic method with a sufficiently large dataset showed a better fit to the theoretical U-value than the results of other dynamic methods proposed by authors. Further research should consider the optimum size of the dataset to obtain a measured U-value that is correctly adjusted to the theoretical U-value. |
| publishDate |
2016 |
| dc.date.none.fl_str_mv |
2016 2016-10-15 2019 2019-04-29 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 AO http://purl.org/coar/version/c_b1a7d7d4d402bcce |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/132231 https://dx.doi.org/10.1016/j.enbuild.2016.08.072 |
| url |
https://hdl.handle.net/2117/132231 https://dx.doi.org/10.1016/j.enbuild.2016.08.072 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivs 3.0 Spain http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivs 3.0 Spain http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869419019805655040 |
| score |
15,198674 |