Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis
The aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data w...
| Autores: | , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2023 |
| País: | España |
| Recursos: | Universitat Autònoma de Barcelona |
| Repositorio: | Dipòsit Digital de Documents de la UAB |
| Idioma: | inglés |
| OAI Identifier: | oai:ddd.uab.cat:284678 |
| Acesso em linha: | https://ddd.uab.cat/record/284678 https://dx.doi.org/urn:doi:10.3390/s23136017 |
| Access Level: | acceso abierto |
| Palavra-chave: | Accelerometer sensor Disability level Fatigue severity Walk tests Wearable device |
| id |
ES_b20cbcdc65fd7d26594bbc9ab7c4ba3e |
|---|---|
| oai_identifier_str |
oai:ddd.uab.cat:284678 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple SclerosisKontaxis, Spyridon|||0000-0002-1297-0691Laporta, Estela|||0000-0001-6776-8522Garcia, Esther|||0000-0003-3997-493XMartinis, MatteoLeocani, Letizia|||0000-0001-9326-6753Roselli, LuciaBuron, Mathias Due|||0000-0003-1260-1156Guerrero, Ana Isabel|||0000-0001-5891-2123Zabalza, Ana|||0000-0003-3860-5251Cummins, NicholasVairavan, SrinivasanHotopf, Matthew|||0000-0002-3980-4466Dobson, Richard James Butler|||0000-0003-4224-9245Narayan, Vaibhav A.La Porta, Maria LiberaCosta, Gloria DallaMagyari, Melinda|||0000-0002-0972-5222Sørensen, Per S|||0000-0002-2818-3780Nos, Carlos|||0000-0002-3830-4910Bailón, Raquel|||0000-0003-1272-0550Comi, Giancarlo|||0000-0002-6989-1054Accelerometer sensorDisability levelFatigue severityWalk testsWearable deviceThe aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data were collected from a total of 323 periodic clinical visits. Accelerometer data from a wearable device during 100 home-based 2MWD assessments were also acquired. The error in estimating the 2MWD was validated for walk tests performed at hospital, and then the correlation (r) between clinical outcomes and home-based 2MWD assessments was evaluated. Robust performance in estimating the 2MWD from the wearable device was obtained, yielding an error of less than 10% in about two-thirds of clinical visits. Correlation analysis showed that there is a strong association between the actual and the estimated 2MWD obtained either at hospital (r = 0.71) or at home (r = 0.58). Furthermore, the estimated 2MWD exhibits moderate-to-strong correlation with various MS-related clinical outcomes, including disability and fatigue severity scores. Automatic assessment of the 2MWD in pwMS is feasible with the usage of a consumer-friendly wearable device in clinical and non-clinical settings. Wearable devices can also enhance the assessment of MS-related clinical outcomes. 22023-01-0120232023-01-01Articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://ddd.uab.cat/record/284678https://dx.doi.org/urn:doi:10.3390/s23136017reponame:Dipòsit Digital de Documents de la UABinstname:Universitat Autònoma de BarcelonaInglésengopen accesshttp://purl.org/coar/access_right/c_abf2Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original.https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:ddd.uab.cat:2846782026-06-06T12:50:31Z |
| dc.title.none.fl_str_mv |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| title |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| spellingShingle |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis Kontaxis, Spyridon|||0000-0002-1297-0691 Accelerometer sensor Disability level Fatigue severity Walk tests Wearable device |
| title_short |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| title_full |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| title_fullStr |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| title_full_unstemmed |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| title_sort |
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis |
| dc.creator.none.fl_str_mv |
Kontaxis, Spyridon|||0000-0002-1297-0691 Laporta, Estela|||0000-0001-6776-8522 Garcia, Esther|||0000-0003-3997-493X Martinis, Matteo Leocani, Letizia|||0000-0001-9326-6753 Roselli, Lucia Buron, Mathias Due|||0000-0003-1260-1156 Guerrero, Ana Isabel|||0000-0001-5891-2123 Zabalza, Ana|||0000-0003-3860-5251 Cummins, Nicholas Vairavan, Srinivasan Hotopf, Matthew|||0000-0002-3980-4466 Dobson, Richard James Butler|||0000-0003-4224-9245 Narayan, Vaibhav A. La Porta, Maria Libera Costa, Gloria Dalla Magyari, Melinda|||0000-0002-0972-5222 Sørensen, Per S|||0000-0002-2818-3780 Nos, Carlos|||0000-0002-3830-4910 Bailón, Raquel|||0000-0003-1272-0550 Comi, Giancarlo|||0000-0002-6989-1054 |
| author |
Kontaxis, Spyridon|||0000-0002-1297-0691 |
| author_facet |
Kontaxis, Spyridon|||0000-0002-1297-0691 Laporta, Estela|||0000-0001-6776-8522 Garcia, Esther|||0000-0003-3997-493X Martinis, Matteo Leocani, Letizia|||0000-0001-9326-6753 Roselli, Lucia Buron, Mathias Due|||0000-0003-1260-1156 Guerrero, Ana Isabel|||0000-0001-5891-2123 Zabalza, Ana|||0000-0003-3860-5251 Cummins, Nicholas Vairavan, Srinivasan Hotopf, Matthew|||0000-0002-3980-4466 Dobson, Richard James Butler|||0000-0003-4224-9245 Narayan, Vaibhav A. La Porta, Maria Libera Costa, Gloria Dalla Magyari, Melinda|||0000-0002-0972-5222 Sørensen, Per S|||0000-0002-2818-3780 Nos, Carlos|||0000-0002-3830-4910 Bailón, Raquel|||0000-0003-1272-0550 Comi, Giancarlo|||0000-0002-6989-1054 |
| author_role |
author |
| author2 |
Laporta, Estela|||0000-0001-6776-8522 Garcia, Esther|||0000-0003-3997-493X Martinis, Matteo Leocani, Letizia|||0000-0001-9326-6753 Roselli, Lucia Buron, Mathias Due|||0000-0003-1260-1156 Guerrero, Ana Isabel|||0000-0001-5891-2123 Zabalza, Ana|||0000-0003-3860-5251 Cummins, Nicholas Vairavan, Srinivasan Hotopf, Matthew|||0000-0002-3980-4466 Dobson, Richard James Butler|||0000-0003-4224-9245 Narayan, Vaibhav A. La Porta, Maria Libera Costa, Gloria Dalla Magyari, Melinda|||0000-0002-0972-5222 Sørensen, Per S|||0000-0002-2818-3780 Nos, Carlos|||0000-0002-3830-4910 Bailón, Raquel|||0000-0003-1272-0550 Comi, Giancarlo|||0000-0002-6989-1054 |
| author2_role |
author author author author author author author author author author author author author author author author author author author author |
| dc.subject.none.fl_str_mv |
Accelerometer sensor Disability level Fatigue severity Walk tests Wearable device |
| topic |
Accelerometer sensor Disability level Fatigue severity Walk tests Wearable device |
| description |
The aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data were collected from a total of 323 periodic clinical visits. Accelerometer data from a wearable device during 100 home-based 2MWD assessments were also acquired. The error in estimating the 2MWD was validated for walk tests performed at hospital, and then the correlation (r) between clinical outcomes and home-based 2MWD assessments was evaluated. Robust performance in estimating the 2MWD from the wearable device was obtained, yielding an error of less than 10% in about two-thirds of clinical visits. Correlation analysis showed that there is a strong association between the actual and the estimated 2MWD obtained either at hospital (r = 0.71) or at home (r = 0.58). Furthermore, the estimated 2MWD exhibits moderate-to-strong correlation with various MS-related clinical outcomes, including disability and fatigue severity scores. Automatic assessment of the 2MWD in pwMS is feasible with the usage of a consumer-friendly wearable device in clinical and non-clinical settings. Wearable devices can also enhance the assessment of MS-related clinical outcomes. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2 2023-01-01 2023 2023-01-01 |
| dc.type.none.fl_str_mv |
Article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://ddd.uab.cat/record/284678 https://dx.doi.org/urn:doi:10.3390/s23136017 |
| url |
https://ddd.uab.cat/record/284678 https://dx.doi.org/urn:doi:10.3390/s23136017 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:Dipòsit Digital de Documents de la UAB instname:Universitat Autònoma de Barcelona |
| instname_str |
Universitat Autònoma de Barcelona |
| reponame_str |
Dipòsit Digital de Documents de la UAB |
| collection |
Dipòsit Digital de Documents de la UAB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869417021033152512 |
| score |
15,301603 |