Shear behaviour of sprayed concrete
Shear in sprayed concrete (SC) may govern the design criteria in certain applications subjected to seismic loads or in bolted areas. However, it has been scarcely studied given the complexity of reproducing the production conditions in the laboratory and the lack of standardized tests. The paper foc...
| Autores: | , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2016 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/89455 |
| Acceso en línea: | https://hdl.handle.net/2117/89455 https://dx.doi.org/10.1016/j.conbuildmat.2016.07.050 |
| Access Level: | acceso abierto |
| Palabra clave: | Shotcrete Luong test Set-accelerator Shear Sprayed concrete Formigó gunitat Àrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó |
| Sumario: | Shear in sprayed concrete (SC) may govern the design criteria in certain applications subjected to seismic loads or in bolted areas. However, it has been scarcely studied given the complexity of reproducing the production conditions in the laboratory and the lack of standardized tests. The paper focuses on the shear characterization of SC using a shear test compatible with the sample production. For that, an experimental program is performed analysing the influence of several parameters and comparing the results to those of a reference concrete. Furthermore, the outcome validates the shear test selected for the characterization of SC. |
|---|