A Robust Lyapunovs Demodulator for Tracking of Single-/Three-Phase Grid Voltage Variables

This article proposes a robust Lyapunovs demodulator (LD) based on an orthogonal signal generation (OSG) approach for single-/three-phase applications. The LD is not normally capable of rejecting the dc-offset in the grid signal, and an additional estimation loop is, therefore, required, which may a...

ver descrição completa

Detalhes bibliográficos
Autores: Verma , Anant Kumar, Subramanian , Chandrasekaran, Jarial , Raj Kumar, Ungarala , Mohan Rao, Roncero Sánchez-Elipe, Pedro Luis
Formato: artículo
Fecha de publicación:2021
País:España
Recursos:Universidad de Castilla-La Mancha
Repositorio:RUIdeRA. Repositorio Institucional de la UCLM
OAI Identifier:oai:ruidera.uclm.es:10578/40257
Acesso em linha:https://hdl.handle.net/10578/40257
Access Level:acceso abierto
Palavra-chave:Amplitude estimation
frequency estimation
Lyapunov’s demodulator
moving average filter (MAF)
phase estimation
Descrição
Resumo:This article proposes a robust Lyapunovs demodulator (LD) based on an orthogonal signal generation (OSG) approach for single-/three-phase applications. The LD is not normally capable of rejecting the dc-offset in the grid signal, and an additional estimation loop is, therefore, required, which may affect the dynamic performance. Nevertheless, an application of a harmonically polluted grid voltage signal to the LD may severely affect the steady-state performance of the parameters estimated. These issues are addressed by proposing an enhanced LD-based-OSG in which a moving average filter is incorporated into the LD-OSG structure. The rapid rejection of dc-offset and harmonics is, therefore, easily achieved without any additional loop. The proposed structure can accurately estimate the fundamental in-phase and quadrature components. However, these orthogonal components may suffer from amplitude imbalance and errors in the phase information under off-nominal frequency conditions. Nevertheless, the errors in the amplitude and the phase information are eliminated using an open-loop frequency deviation detector and a feed-forward curve-fitting approach. The dynamic performance of the proposed scheme has been validated by means of numerical and hardware studies whose results show that, with the less sensitivity toward the phase angle jump and good immunity to the fundamental negative sequence, the proposed scheme is a potential technique with which to synchronize single-/three-phase grid-connected power electronic equipment.