Noninvasive Monitoring to Detect Dehydration: Are We There Yet?

29 pags., 4 figs., 2 tabs.

Detalhes bibliográficos
Autores: Gray, Martha, Birkenfeld, Judith S., Butterworth, Ian
Tipo de documento: artigo
Estado:Versão publicada
Data de publicação:2023
País:España
Recursos:Consejo Superior de Investigaciones Científicas (CSIC)
Repositório:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/350321
Acesso em linha:http://hdl.handle.net/10261/350321
https://api.elsevier.com/content/abstract/scopus_id/85163332410
Access Level:Acceso aberto
Palavra-chave:Dehydration detection
Hydration
Hydration monitoring
Medical devices
Wearable devices
id ES_aa71c0be55edf0134ddbb215c5ebcf5d
oai_identifier_str oai:digital.csic.es:10261/350321
network_acronym_str ES
network_name_str España
repository_id_str
spelling Noninvasive Monitoring to Detect Dehydration: Are We There Yet?Gray, MarthaBirkenfeld, Judith S.Butterworth, IanDehydration detectionHydrationHydration monitoringMedical devicesWearable devices29 pags., 4 figs., 2 tabs.The need for hydration monitoring is significant, especially for the very young and elderly populations who are more vulnerable to becoming dehydrated and suffering from the effects that dehydration brings. This need has been among the drivers of considerable effort in the academic and commercial sectors to provide a means for monitoring hydration status, with a special interest in doing so outside the hospital or clinical setting. This review of emerging technologies provides an overview of many technology approaches that, on a theoretical basis, have sensitivity to water and are feasible as a routine measurement. We review the evidence of technical validation and of their use in humans. Finally, we highlight the essential need for these technologies to be rigorously evaluated for their diagnostic potential, as a necessary step to meet the need for hydration monitoring outside of the clinical environment.The authors have been partially supported by grants from the Massachusetts Institute of Technology (MIT)’s Deshpande Center for Technological Innovation, the Madrid-MIT M+Visión Consortium, the National Institutes of Health Point of Care Translational Research Network, Massachusetts General Hospital/Center for Integration of Medicine and Innovative Technology, and the MIT Center for Clinical and Translational Research.Peer reviewedAnnual ReviewsMassachusetts Institute of TechnologyNational Institutes of Health (US)Massachusetts General Hospital#NODATA##NODATA##NODATA#Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]202420242023info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501Publisher's versioninfo:eu-repo/semantics/publishedVersionhttp://hdl.handle.net/10261/350321https://api.elsevier.com/content/abstract/scopus_id/85163332410reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)InglésAnnual review of biomedical engineeringhttps://doi.org/10.1146/annurev-bioeng-062117-121028Síinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/3503212026-05-22T06:33:51Z
dc.title.none.fl_str_mv Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
title Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
spellingShingle Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
Gray, Martha
Dehydration detection
Hydration
Hydration monitoring
Medical devices
Wearable devices
title_short Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
title_full Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
title_fullStr Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
title_full_unstemmed Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
title_sort Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
dc.creator.none.fl_str_mv Gray, Martha
Birkenfeld, Judith S.
Butterworth, Ian
author Gray, Martha
author_facet Gray, Martha
Birkenfeld, Judith S.
Butterworth, Ian
author_role author
author2 Birkenfeld, Judith S.
Butterworth, Ian
author2_role author
author
dc.contributor.none.fl_str_mv Massachusetts Institute of Technology
National Institutes of Health (US)
Massachusetts General Hospital
#NODATA#
#NODATA#
#NODATA#
Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]
dc.subject.none.fl_str_mv Dehydration detection
Hydration
Hydration monitoring
Medical devices
Wearable devices
topic Dehydration detection
Hydration
Hydration monitoring
Medical devices
Wearable devices
description 29 pags., 4 figs., 2 tabs.
publishDate 2023
dc.date.none.fl_str_mv 2023
2024
2024
dc.type.none.fl_str_mv info:eu-repo/semantics/article
http://purl.org/coar/resource_type/c_6501
Publisher's version
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10261/350321
https://api.elsevier.com/content/abstract/scopus_id/85163332410
url http://hdl.handle.net/10261/350321
https://api.elsevier.com/content/abstract/scopus_id/85163332410
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Annual review of biomedical engineering
https://doi.org/10.1146/annurev-bioeng-062117-121028

dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Annual Reviews
publisher.none.fl_str_mv Annual Reviews
dc.source.none.fl_str_mv reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC
instname:Consejo Superior de Investigaciones Científicas (CSIC)
instname_str Consejo Superior de Investigaciones Científicas (CSIC)
reponame_str DIGITAL.CSIC. Repositorio Institucional del CSIC
collection DIGITAL.CSIC. Repositorio Institucional del CSIC
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416182249947136
score 15,81155