Dose assesment with fast Monte Carlo codes in interventional radiology

This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator...

ver descrição completa

Detalhes bibliográficos
Autores: García Balcaza, Víctor|||0000-0003-0029-8436, Camp Brunés, Anna|||0000-0002-4736-5598, Sánchez Casanueva, Roberto Mariano, Ginjaume Egido, Mercè|||0000-0002-6767-2624, Duch Guillen, María Amor|||0000-0002-1560-1576
Formato: artículo
Fecha de publicación:2023
País:España
Recursos:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/399247
Acesso em linha:https://hdl.handle.net/2117/399247
https://dx.doi.org/10.1093/rpd/ncac244
Access Level:acceso abierto
Palavra-chave:Monte Carlo method
Radiation--Safety measures
Numerical analysis
Interventional radiology
Monte Carlo
PyMCGPU-IR
Montecarlo, Mètode de
Radiació--Mesures de seguretat
Anàlisi numèrica
Àrees temàtiques de la UPC::Enginyeria biomèdica
id ES_a62b4df67d06130232afa35de6504e10
oai_identifier_str oai:upcommons.upc.edu:2117/399247
network_acronym_str ES
network_name_str España
repository_id_str
spelling Dose assesment with fast Monte Carlo codes in interventional radiologyGarcía Balcaza, Víctor|||0000-0003-0029-8436Camp Brunés, Anna|||0000-0002-4736-5598Sánchez Casanueva, Roberto MarianoGinjaume Egido, Mercè|||0000-0002-6767-2624Duch Guillen, María Amor|||0000-0002-1560-1576Monte Carlo methodRadiation--Safety measuresNumerical analysisInterventional radiologyMonte CarloPyMCGPU-IRMontecarlo, Mètode deRadiació--Mesures de seguretatAnàlisi numèricaÀrees temàtiques de la UPC::Enginyeria biomèdicaThis study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.This work was partially supported by EJP-CONCERT for 2014–2018 (662287); the Ministerio de Economía y Competitividad (PCIN-2017-044); and the Spanish Nuclear Safety Council through project EDOCI and the ‘Cátedra Argos’.Objectius de Desenvolupament Sostenible::3 - Salut i Benestar20232023-10-1120242024-01-12journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/399247https://dx.doi.org/10.1093/rpd/ncac244reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)InglésengAgencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación (PEICTI) 2013-2016 PCIN-2017-044 DOSIMETRIA PERSONAL EN LINEA (ONLINE) UTILIZANDO METODOS COMPUTACIONALESEuropean Commission http://doi.org/10.13039/100010661 Horizon 2020 Framework Programme 662287 European Joint Programme for the Integration of Radiation Protection Researchopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/3992472026-05-27T15:37:01Z
dc.title.none.fl_str_mv Dose assesment with fast Monte Carlo codes in interventional radiology
title Dose assesment with fast Monte Carlo codes in interventional radiology
spellingShingle Dose assesment with fast Monte Carlo codes in interventional radiology
García Balcaza, Víctor|||0000-0003-0029-8436
Monte Carlo method
Radiation--Safety measures
Numerical analysis
Interventional radiology
Monte Carlo
PyMCGPU-IR
Montecarlo, Mètode de
Radiació--Mesures de seguretat
Anàlisi numèrica
Àrees temàtiques de la UPC::Enginyeria biomèdica
title_short Dose assesment with fast Monte Carlo codes in interventional radiology
title_full Dose assesment with fast Monte Carlo codes in interventional radiology
title_fullStr Dose assesment with fast Monte Carlo codes in interventional radiology
title_full_unstemmed Dose assesment with fast Monte Carlo codes in interventional radiology
title_sort Dose assesment with fast Monte Carlo codes in interventional radiology
dc.creator.none.fl_str_mv García Balcaza, Víctor|||0000-0003-0029-8436
Camp Brunés, Anna|||0000-0002-4736-5598
Sánchez Casanueva, Roberto Mariano
Ginjaume Egido, Mercè|||0000-0002-6767-2624
Duch Guillen, María Amor|||0000-0002-1560-1576
author García Balcaza, Víctor|||0000-0003-0029-8436
author_facet García Balcaza, Víctor|||0000-0003-0029-8436
Camp Brunés, Anna|||0000-0002-4736-5598
Sánchez Casanueva, Roberto Mariano
Ginjaume Egido, Mercè|||0000-0002-6767-2624
Duch Guillen, María Amor|||0000-0002-1560-1576
author_role author
author2 Camp Brunés, Anna|||0000-0002-4736-5598
Sánchez Casanueva, Roberto Mariano
Ginjaume Egido, Mercè|||0000-0002-6767-2624
Duch Guillen, María Amor|||0000-0002-1560-1576
author2_role author
author
author
author
dc.subject.none.fl_str_mv Monte Carlo method
Radiation--Safety measures
Numerical analysis
Interventional radiology
Monte Carlo
PyMCGPU-IR
Montecarlo, Mètode de
Radiació--Mesures de seguretat
Anàlisi numèrica
Àrees temàtiques de la UPC::Enginyeria biomèdica
topic Monte Carlo method
Radiation--Safety measures
Numerical analysis
Interventional radiology
Monte Carlo
PyMCGPU-IR
Montecarlo, Mètode de
Radiació--Mesures de seguretat
Anàlisi numèrica
Àrees temàtiques de la UPC::Enginyeria biomèdica
description This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.
publishDate 2023
dc.date.none.fl_str_mv 2023
2023-10-11
2024
2024-01-12
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
AM
http://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/2117/399247
https://dx.doi.org/10.1093/rpd/ncac244
url https://hdl.handle.net/2117/399247
https://dx.doi.org/10.1093/rpd/ncac244
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.relation.none.fl_str_mv Agencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación (PEICTI) 2013-2016 PCIN-2017-044 DOSIMETRIA PERSONAL EN LINEA (ONLINE) UTILIZANDO METODOS COMPUTACIONALES
European Commission http://doi.org/10.13039/100010661 Horizon 2020 Framework Programme 662287 European Joint Programme for the Integration of Radiation Protection Research
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:UPCommons. Portal del coneixement obert de la UPC
instname:Universitat Politècnica de Catalunya (UPC)
instname_str Universitat Politècnica de Catalunya (UPC)
reponame_str UPCommons. Portal del coneixement obert de la UPC
collection UPCommons. Portal del coneixement obert de la UPC
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869415675935588352
score 15.301603