Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System

[EN] Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especiall...

Descripción completa

Detalles Bibliográficos
Autores: Camilo Rosado, Luis E., López Jiménez, Petra Amparo|||0000-0002-7043-3683, Sánchez-Romero, Francisco-Javier|||0000-0003-1447-6897, CONEJOS FUERTES, PILAR|||0000-0002-6446-4715, Pérez-Sánchez, Modesto|||0000-0001-8316-7778
Tipo de recurso: artículo
Fecha de publicación:2020
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/162963
Acceso en línea:https://riunet.upv.es/handle/10251/162963
Access Level:acceso abierto
Palabra clave:PATs
Recovery
Energy
Sustainability
Supply
INGENIERIA HIDRAULICA
INGENIERIA AGROFORESTAL
09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación
07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos
id ES_a4d543f0668465ca5cc3483323809ef2
oai_identifier_str oai:riunet.upv.es:10251/162963
network_acronym_str ES
network_name_str España
repository_id_str
spelling Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply SystemCamilo Rosado, Luis E.López Jiménez, Petra Amparo|||0000-0002-7043-3683Sánchez-Romero, Francisco-Javier|||0000-0003-1447-6897CONEJOS FUERTES, PILAR|||0000-0002-6446-4715Pérez-Sánchez, Modesto|||0000-0001-8316-7778PATsRecoveryEnergySustainabilitySupplyINGENIERIA HIDRAULICAINGENIERIA AGROFORESTAL09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos[EN] Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especially in pressurized water distribution systems, the use of pressure reduction valves (PRVs) increases the water usage efficiency but it decreases the energy consumption efficiency, since the valves dissipate energy that could be recovered. This research presents a proposal of a recovery system based on the installation of pumps used as turbines (PATs). These machines are located in different points of the high-pressure water distribution system in the Valencia Metropolitan System (Spain). An annual estimate of the theoretical recoverable energy as well as the "ideal" pump for each point were proposed. The theoretical recovered energy value was 847,301 kWh/year for a specific analyzed point. Besides, the characteristic curves of thePATsfrom a selected point were determined, estimating an improvement in the sustainable indexes. The calculus of these green parameters showed that the implementation of this solution caused a reduction in consumed energy of 1.50 kWh/m(3).Authors greatly acknowledge financial support from the "Catedra Aguas de Valencia" in the grant "Analysis of recoverable hydraulic energy using recovery systems in supply systems" for the first author of this contribution.MDPI AGDepartamento de Ingeniería Hidráulica y Medio AmbienteDepartamento de Ingeniería Rural y AgroalimentariaEscuela Técnica Superior de Ingeniería IndustrialEscuela Politécnica Superior de AlcoyEscuela Técnica Superior de Ingeniería Agronómica y del Medio NaturalCátedra Aguas de Valencia, Universitat Politècnica de ValènciaRepositorio Institucional de la Universitat Politècnica de València Riunet20202020-06-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/162963reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento (by)http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1629632026-06-13T07:49:27Z
dc.title.none.fl_str_mv Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
title Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
spellingShingle Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
Camilo Rosado, Luis E.
PATs
Recovery
Energy
Sustainability
Supply
INGENIERIA HIDRAULICA
INGENIERIA AGROFORESTAL
09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación
07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos
title_short Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
title_full Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
title_fullStr Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
title_full_unstemmed Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
title_sort Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
dc.creator.none.fl_str_mv Camilo Rosado, Luis E.
López Jiménez, Petra Amparo|||0000-0002-7043-3683
Sánchez-Romero, Francisco-Javier|||0000-0003-1447-6897
CONEJOS FUERTES, PILAR|||0000-0002-6446-4715
Pérez-Sánchez, Modesto|||0000-0001-8316-7778
author Camilo Rosado, Luis E.
author_facet Camilo Rosado, Luis E.
López Jiménez, Petra Amparo|||0000-0002-7043-3683
Sánchez-Romero, Francisco-Javier|||0000-0003-1447-6897
CONEJOS FUERTES, PILAR|||0000-0002-6446-4715
Pérez-Sánchez, Modesto|||0000-0001-8316-7778
author_role author
author2 López Jiménez, Petra Amparo|||0000-0002-7043-3683
Sánchez-Romero, Francisco-Javier|||0000-0003-1447-6897
CONEJOS FUERTES, PILAR|||0000-0002-6446-4715
Pérez-Sánchez, Modesto|||0000-0001-8316-7778
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Departamento de Ingeniería Hidráulica y Medio Ambiente
Departamento de Ingeniería Rural y Agroalimentaria
Escuela Técnica Superior de Ingeniería Industrial
Escuela Politécnica Superior de Alcoy
Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural
Cátedra Aguas de Valencia, Universitat Politècnica de València
Repositorio Institucional de la Universitat Politècnica de València Riunet
dc.subject.none.fl_str_mv PATs
Recovery
Energy
Sustainability
Supply
INGENIERIA HIDRAULICA
INGENIERIA AGROFORESTAL
09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación
07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos
topic PATs
Recovery
Energy
Sustainability
Supply
INGENIERIA HIDRAULICA
INGENIERIA AGROFORESTAL
09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación
07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos
description [EN] Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especially in pressurized water distribution systems, the use of pressure reduction valves (PRVs) increases the water usage efficiency but it decreases the energy consumption efficiency, since the valves dissipate energy that could be recovered. This research presents a proposal of a recovery system based on the installation of pumps used as turbines (PATs). These machines are located in different points of the high-pressure water distribution system in the Valencia Metropolitan System (Spain). An annual estimate of the theoretical recoverable energy as well as the "ideal" pump for each point were proposed. The theoretical recovered energy value was 847,301 kWh/year for a specific analyzed point. Besides, the characteristic curves of thePATsfrom a selected point were determined, estimating an improvement in the sustainable indexes. The calculus of these green parameters showed that the implementation of this solution caused a reduction in consumed energy of 1.50 kWh/m(3).
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-06-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://riunet.upv.es/handle/10251/162963
url https://riunet.upv.es/handle/10251/162963
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reconocimiento (by)
http://creativecommons.org/licenses/by/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reconocimiento (by)
http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI AG
publisher.none.fl_str_mv MDPI AG
dc.source.none.fl_str_mv reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
instname:Universitat Politècnica de València (UPV)
instname_str Universitat Politècnica de València (UPV)
reponame_str RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
collection RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869415547364442112
score 15,198674