Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System

[EN] Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especiall...

Descripción completa

Detalles Bibliográficos
Autores: Camilo Rosado, Luis E., López Jiménez, Petra Amparo|||0000-0002-7043-3683, Sánchez-Romero, Francisco-Javier|||0000-0003-1447-6897, CONEJOS FUERTES, PILAR|||0000-0002-6446-4715, Pérez-Sánchez, Modesto|||0000-0001-8316-7778
Tipo de recurso: artículo
Fecha de publicación:2020
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/162963
Acceso en línea:https://riunet.upv.es/handle/10251/162963
Access Level:acceso abierto
Palabra clave:PATs
Recovery
Energy
Sustainability
Supply
INGENIERIA HIDRAULICA
INGENIERIA AGROFORESTAL
09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación
07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos
Descripción
Sumario:[EN] Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especially in pressurized water distribution systems, the use of pressure reduction valves (PRVs) increases the water usage efficiency but it decreases the energy consumption efficiency, since the valves dissipate energy that could be recovered. This research presents a proposal of a recovery system based on the installation of pumps used as turbines (PATs). These machines are located in different points of the high-pressure water distribution system in the Valencia Metropolitan System (Spain). An annual estimate of the theoretical recoverable energy as well as the "ideal" pump for each point were proposed. The theoretical recovered energy value was 847,301 kWh/year for a specific analyzed point. Besides, the characteristic curves of thePATsfrom a selected point were determined, estimating an improvement in the sustainable indexes. The calculus of these green parameters showed that the implementation of this solution caused a reduction in consumed energy of 1.50 kWh/m(3).