On the Modeling of Microstrip Lines Loaded With Dumbbell Defect-Ground-Structure (DB-DGS) and Folded DB-DGS Resonators

This paper presents a lumped-element equivalent circuit model of microstrip lines loaded with dumbbell defect-ground-structure (DB-DGS) resonators, etched in the ground plane. The model is valid for ordinary (i.e., unfolded) DB-DGSs, as well as for folded DB-DGSs with an arbitrary aperture angle and...

Descripción completa

Detalles Bibliográficos
Autores: Su, Lijuan|||0000-0002-4753-9340, Muñoz Enano, Jonathan|||0000-0003-1271-3801, Vélez, Paris|||0000-0001-6502-5987, Martel Villagrán, Jesús|||0000-0002-2705-5912, Medina, Francisco|||0000-0002-9947-506X, Martín, Ferran|||0000-0002-1494-9167
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universitat Autònoma de Barcelona
Repositorio:Dipòsit Digital de Documents de la UAB
Idioma:inglés
OAI Identifier:oai:ddd.uab.cat:258219
Acceso en línea:https://ddd.uab.cat/record/258219
https://dx.doi.org/urn:doi:10.1109/ACCESS.2021.3125775
Access Level:acceso abierto
Palabra clave:Dumbbell DGS (DB-DGS)
Defect ground structures (DGS)
Folded DB-DGS
Mixed coupling
Microstrip technology
Parameter extraction
Descripción
Sumario:This paper presents a lumped-element equivalent circuit model of microstrip lines loaded with dumbbell defect-ground-structure (DB-DGS) resonators, etched in the ground plane. The model is valid for ordinary (i.e., unfolded) DB-DGSs, as well as for folded DB-DGSs with an arbitrary aperture angle and relative orientation between the line and the resonator. It is shown that in folded, or partially folded, DB-DGS resonators both magnetic and electric coupling between the line and the resonator should be considered, except for a particular DB-DGS orientation, namely, the one where the symmetry plane of the particle (a magnetic wall) is orthogonal to the line axis. In this case, the particle is exclusively excited by the electric field generated by the line. It is also shown that the circuit model of a microstrip line loaded with an unfolded DB-DGS resonator transversally oriented to the line can be derived from the general model by considering the effects of opening the particle, i.e., a reduction of the electric coupling. In the extreme situation where the DB-DGS is completely opened (unfolded), the electric coupling vanishes, and the particle is exclusively driven by the magnetic field generated by the line. This effect is taken into account in the model by considering that the capacitance between the line and the inner metallic region of the folded, or partially folded, DB-DGS depends on the aperture angle of the particle, and it is null when the particle is unfolded. The models are validated by parameter extraction and comparison of the circuit responses with the responses inferred by electromagnetic simulation and measurement.