A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers

The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed...

Descripción completa

Detalles Bibliográficos
Autores: López Muñoz, Alfredo, López Castaño, Isabel, Torres Parejo, Úrsula, García Romera, Marta de la Concepción
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2023
País:España
Institución:Universidad de Sevilla (US)
Repositorio:idUS. Depósito de Investigación de la Universidad de Sevilla
OAI Identifier:oai:idus.us.es:11441/152422
Acceso en línea:https://hdl.handle.net/11441/152422
https://doi.org/10.3390/life13122313
Access Level:acceso abierto
Palabra clave:myopia
soft contact lenses
corneal biomechanics
Scheimpflug technology
Corvis ST®
id ES_94895ccc034120077ce63a476a28bb2f
oai_identifier_str oai:idus.us.es:11441/152422
network_acronym_str ES
network_name_str España
repository_id_str
spelling A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens WearersLópez Muñoz, AlfredoLópez Castaño, IsabelTorres Parejo, ÚrsulaGarcía Romera, Marta de la Concepciónmyopiasoft contact lensescorneal biomechanicsScheimpflug technologyCorvis ST®The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.MDPIFísica de la Materia Condensada2023info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/152422https://doi.org/10.3390/life13122313reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésLife, 13 (12), 2313.https://doi.org/10.3390/life13122313info:eu-repo/semantics/openAccessoai:idus.us.es:11441/1524222026-06-17T12:51:07Z
dc.title.none.fl_str_mv A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
title A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
spellingShingle A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
López Muñoz, Alfredo
myopia
soft contact lenses
corneal biomechanics
Scheimpflug technology
Corvis ST®
title_short A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
title_full A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
title_fullStr A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
title_full_unstemmed A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
title_sort A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
dc.creator.none.fl_str_mv López Muñoz, Alfredo
López Castaño, Isabel
Torres Parejo, Úrsula
García Romera, Marta de la Concepción
author López Muñoz, Alfredo
author_facet López Muñoz, Alfredo
López Castaño, Isabel
Torres Parejo, Úrsula
García Romera, Marta de la Concepción
author_role author
author2 López Castaño, Isabel
Torres Parejo, Úrsula
García Romera, Marta de la Concepción
author2_role author
author
author
dc.contributor.none.fl_str_mv Física de la Materia Condensada
dc.subject.none.fl_str_mv myopia
soft contact lenses
corneal biomechanics
Scheimpflug technology
Corvis ST®
topic myopia
soft contact lenses
corneal biomechanics
Scheimpflug technology
Corvis ST®
description The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.
publishDate 2023
dc.date.none.fl_str_mv 2023
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/11441/152422
https://doi.org/10.3390/life13122313
url https://hdl.handle.net/11441/152422
https://doi.org/10.3390/life13122313
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Life, 13 (12), 2313.
https://doi.org/10.3390/life13122313
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:idUS. Depósito de Investigación de la Universidad de Sevilla
instname:Universidad de Sevilla (US)
instname_str Universidad de Sevilla (US)
reponame_str idUS. Depósito de Investigación de la Universidad de Sevilla
collection idUS. Depósito de Investigación de la Universidad de Sevilla
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869413702320521216
score 15,301603