Are Oxygen-Conserving Devices Effective for Correcting Exercise Hypoxemia?
BACKGROUND: Correction of exercise hypoxemia in advanced lung diseases is crucial and often challenging. However, oxygen-conserving devices have been introduced in the market with limited evidence of effectiveness. In the present study the efficacy of 2 oxygen-conserving devices, a pulse demand oxyg...
| Authors: | , , , , , , |
|---|---|
| Format: | article |
| Status: | Published version |
| Publication Date: | 2013 |
| Country: | España |
| Institution: | Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau) |
| Repository: | r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau |
| OAI Identifier: | oai:iibsantpau.fundanetsuite.com:p9655 |
| Online Access: | https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=9655 |
| Access Level: | Open access |
| Keyword: | COPD conservers exercise test interstitial lung disease oxygen inhalation therapy technology assessment |
| Summary: | BACKGROUND: Correction of exercise hypoxemia in advanced lung diseases is crucial and often challenging. However, oxygen-conserving devices have been introduced in the market with limited evidence of effectiveness. In the present study the efficacy of 2 oxygen-conserving devices, a pulse demand oxygen delivery (DOD) system and pendant reservoir cannula (PRC), were evaluated in subjects with COPD and interstitial lung disease (ILD). METHODS: A cross-sectional, crossover study included 28 COPD and 31 ILD subjects with oxygen desaturation on the 6-min walk test (average S-pO2 < 88%). Each subject underwent 3 walk tests with DOD, PRC, and continuous oxygen flow by standard nasal cannula (CFNC), in random order, taking average S-pO2 >= 90% as the resaturation criterion. RESULTS: Exercise desaturation was corrected in 79%, 79%, and 86% of COPD subjects with CFNC, DOD, and PRC, respectively, and in 77%, 61%, and 81% of ILD subjects with CFNC, DOD, and PRC, respectively. When compared to CFNC, the oxygen-conserving devices showed similar efficacy, except a lower performance for the DOD in the ILD subjects (P = .01). CONCLUSIONS: Although these oxygen-conserving devices corrected exercise hypoxemia in most COPD and ILD subjects, correction was not achieved in about 20% of the severe COPD subjects, regardless of the device, and in nearly 40% of the ILD subjects with the DOD device. These findings underscore that individualized adjustment of oxygen flow is needed for optimal correction of exercise hypoxemia, especially with a DOD in an ILD patient. |
|---|