Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population
FreeStyle Libre ® 2 system is a sensor-based flash-monitoring system that measures interstitial fluid glucose. The study aimed to compare cost of FreeStyle Libre 2 system and self-monitoring of blood glucose (SMBG) in the type 2 diabetes mellitus (T2DM) population from the Spanish Health System pers...
| Autores: | , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2021 |
| País: | España |
| Institución: | Universitat Autònoma de Barcelona |
| Repositorio: | Dipòsit Digital de Documents de la UAB |
| Idioma: | inglés |
| OAI Identifier: | oai:ddd.uab.cat:255550 |
| Acceso en línea: | https://ddd.uab.cat/record/255550 https://dx.doi.org/urn:doi:10.1007/s13300-021-01064-4 |
| Access Level: | acceso abierto |
| Palabra clave: | Cost Diabetes Flash FreeStyle Libre Glucose monitoring |
| id |
ES_911a374d7d2d2cdb73d5c79aa5319bfb |
|---|---|
| oai_identifier_str |
oai:ddd.uab.cat:255550 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus PopulationOyagüez, Itziar|||0000-0002-3047-6152Gómez-Peralta, Fernando|||0000-0003-0106-0091Artola, Sara|||0000-0002-6713-7197Carrasco Trancoso, Francisco JavierCarretero-Gómez, JuanaGarcía-Soidan, JavierGomez Huelgas, RicardoMerino Torres, Juan Francisco|||0000-0002-0191-4504Pérez, Antonio|||0000-0001-5528-1143CostDiabetesFlashFreeStyle LibreGlucose monitoringFreeStyle Libre ® 2 system is a sensor-based flash-monitoring system that measures interstitial fluid glucose. The study aimed to compare cost of FreeStyle Libre 2 system and self-monitoring of blood glucose (SMBG) in the type 2 diabetes mellitus (T2DM) population from the Spanish Health System perspective. On the basis of data collected from a literature review, the cost of glucose monitoring was modelled for patients with T2DM on a basal-bolus insulin regimen. The cost estimate included annual consumption for glucose monitoring (strips, lancets and sensors) and severe hypoglycaemic events (SHE) management. A published rate of SHE (2.5 episodes/patient-year) was considered. A reduction of SHE (- 48.8%) associated with FreeStyle Libre 2 system, derived from the REPLACE trial, was applied. Hospital attendance for 20.5% of SHEs (with subsequent hospitalization in 16.0%) was applied. Consumption of strips and lancets was set at 6/day for SMBG (derived from national monitoring recommendations), and 0.2/day for FreeStyle Libre 2 system users, with 26 FreeStyle Libre 2 sensors/year. Unitary costs (€, year 2020 excluding VAT) were derived from literature (€0.28/strip; €0.09/lancet; €3.09/daily FM sensor; €3804/hospitalized SHE; €1794/hospital-attended non-admitted SHE; €389/community-attended SHE). Costs were €2700 and €2120/year/patient using SMBG or FreeStyle Libre 2 system, respectively. For 1000 patients with T2DM using basal-bolus insulin, 1220 SHEs/year (with 48 hospitalizations) could be prevented and FreeSytle Libre 2 system could generate cost savings of up to €580,953/year versus SMBG (- 21.5%). FreeStyle Libre 2 system is a potential cost-saving strategy in patients with T2DM in Spain on a basal-bolus insulin regimen.Universitat Autònoma de Barcelona 22021-01-0120212021-01-01Articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://ddd.uab.cat/record/255550https://dx.doi.org/urn:doi:10.1007/s13300-021-01064-4reponame:Dipòsit Digital de Documents de la UABinstname:Universitat Autònoma de BarcelonaInglésengopen accesshttp://purl.org/coar/access_right/c_abf2Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original.https://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessoai:ddd.uab.cat:2555502026-06-06T12:50:31Z |
| dc.title.none.fl_str_mv |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| title |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| spellingShingle |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population Oyagüez, Itziar|||0000-0002-3047-6152 Cost Diabetes Flash FreeStyle Libre Glucose monitoring |
| title_short |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| title_full |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| title_fullStr |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| title_full_unstemmed |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| title_sort |
Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population |
| dc.creator.none.fl_str_mv |
Oyagüez, Itziar|||0000-0002-3047-6152 Gómez-Peralta, Fernando|||0000-0003-0106-0091 Artola, Sara|||0000-0002-6713-7197 Carrasco Trancoso, Francisco Javier Carretero-Gómez, Juana García-Soidan, Javier Gomez Huelgas, Ricardo Merino Torres, Juan Francisco|||0000-0002-0191-4504 Pérez, Antonio|||0000-0001-5528-1143 |
| author |
Oyagüez, Itziar|||0000-0002-3047-6152 |
| author_facet |
Oyagüez, Itziar|||0000-0002-3047-6152 Gómez-Peralta, Fernando|||0000-0003-0106-0091 Artola, Sara|||0000-0002-6713-7197 Carrasco Trancoso, Francisco Javier Carretero-Gómez, Juana García-Soidan, Javier Gomez Huelgas, Ricardo Merino Torres, Juan Francisco|||0000-0002-0191-4504 Pérez, Antonio|||0000-0001-5528-1143 |
| author_role |
author |
| author2 |
Gómez-Peralta, Fernando|||0000-0003-0106-0091 Artola, Sara|||0000-0002-6713-7197 Carrasco Trancoso, Francisco Javier Carretero-Gómez, Juana García-Soidan, Javier Gomez Huelgas, Ricardo Merino Torres, Juan Francisco|||0000-0002-0191-4504 Pérez, Antonio|||0000-0001-5528-1143 |
| author2_role |
author author author author author author author author |
| dc.contributor.none.fl_str_mv |
Universitat Autònoma de Barcelona |
| dc.subject.none.fl_str_mv |
Cost Diabetes Flash FreeStyle Libre Glucose monitoring |
| topic |
Cost Diabetes Flash FreeStyle Libre Glucose monitoring |
| description |
FreeStyle Libre ® 2 system is a sensor-based flash-monitoring system that measures interstitial fluid glucose. The study aimed to compare cost of FreeStyle Libre 2 system and self-monitoring of blood glucose (SMBG) in the type 2 diabetes mellitus (T2DM) population from the Spanish Health System perspective. On the basis of data collected from a literature review, the cost of glucose monitoring was modelled for patients with T2DM on a basal-bolus insulin regimen. The cost estimate included annual consumption for glucose monitoring (strips, lancets and sensors) and severe hypoglycaemic events (SHE) management. A published rate of SHE (2.5 episodes/patient-year) was considered. A reduction of SHE (- 48.8%) associated with FreeStyle Libre 2 system, derived from the REPLACE trial, was applied. Hospital attendance for 20.5% of SHEs (with subsequent hospitalization in 16.0%) was applied. Consumption of strips and lancets was set at 6/day for SMBG (derived from national monitoring recommendations), and 0.2/day for FreeStyle Libre 2 system users, with 26 FreeStyle Libre 2 sensors/year. Unitary costs (€, year 2020 excluding VAT) were derived from literature (€0.28/strip; €0.09/lancet; €3.09/daily FM sensor; €3804/hospitalized SHE; €1794/hospital-attended non-admitted SHE; €389/community-attended SHE). Costs were €2700 and €2120/year/patient using SMBG or FreeStyle Libre 2 system, respectively. For 1000 patients with T2DM using basal-bolus insulin, 1220 SHEs/year (with 48 hospitalizations) could be prevented and FreeSytle Libre 2 system could generate cost savings of up to €580,953/year versus SMBG (- 21.5%). FreeStyle Libre 2 system is a potential cost-saving strategy in patients with T2DM in Spain on a basal-bolus insulin regimen. |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2 2021-01-01 2021 2021-01-01 |
| dc.type.none.fl_str_mv |
Article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://ddd.uab.cat/record/255550 https://dx.doi.org/urn:doi:10.1007/s13300-021-01064-4 |
| url |
https://ddd.uab.cat/record/255550 https://dx.doi.org/urn:doi:10.1007/s13300-021-01064-4 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by-nc/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by-nc/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:Dipòsit Digital de Documents de la UAB instname:Universitat Autònoma de Barcelona |
| instname_str |
Universitat Autònoma de Barcelona |
| reponame_str |
Dipòsit Digital de Documents de la UAB |
| collection |
Dipòsit Digital de Documents de la UAB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869413363079970816 |
| score |
15.301629 |