Cost Analysis of FreeStyle Libre ® 2 System in Type 2 Diabetes Mellitus Population

FreeStyle Libre ® 2 system is a sensor-based flash-monitoring system that measures interstitial fluid glucose. The study aimed to compare cost of FreeStyle Libre 2 system and self-monitoring of blood glucose (SMBG) in the type 2 diabetes mellitus (T2DM) population from the Spanish Health System pers...

Descripción completa

Detalles Bibliográficos
Autores: Oyagüez, Itziar|||0000-0002-3047-6152, Gómez-Peralta, Fernando|||0000-0003-0106-0091, Artola, Sara|||0000-0002-6713-7197, Carrasco Trancoso, Francisco Javier, Carretero-Gómez, Juana, García-Soidan, Javier, Gomez Huelgas, Ricardo, Merino Torres, Juan Francisco|||0000-0002-0191-4504, Pérez, Antonio|||0000-0001-5528-1143
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universitat Autònoma de Barcelona
Repositorio:Dipòsit Digital de Documents de la UAB
Idioma:inglés
OAI Identifier:oai:ddd.uab.cat:255550
Acceso en línea:https://ddd.uab.cat/record/255550
https://dx.doi.org/urn:doi:10.1007/s13300-021-01064-4
Access Level:acceso abierto
Palabra clave:Cost
Diabetes
Flash
FreeStyle Libre
Glucose monitoring
Descripción
Sumario:FreeStyle Libre ® 2 system is a sensor-based flash-monitoring system that measures interstitial fluid glucose. The study aimed to compare cost of FreeStyle Libre 2 system and self-monitoring of blood glucose (SMBG) in the type 2 diabetes mellitus (T2DM) population from the Spanish Health System perspective. On the basis of data collected from a literature review, the cost of glucose monitoring was modelled for patients with T2DM on a basal-bolus insulin regimen. The cost estimate included annual consumption for glucose monitoring (strips, lancets and sensors) and severe hypoglycaemic events (SHE) management. A published rate of SHE (2.5 episodes/patient-year) was considered. A reduction of SHE (- 48.8%) associated with FreeStyle Libre 2 system, derived from the REPLACE trial, was applied. Hospital attendance for 20.5% of SHEs (with subsequent hospitalization in 16.0%) was applied. Consumption of strips and lancets was set at 6/day for SMBG (derived from national monitoring recommendations), and 0.2/day for FreeStyle Libre 2 system users, with 26 FreeStyle Libre 2 sensors/year. Unitary costs (€, year 2020 excluding VAT) were derived from literature (€0.28/strip; €0.09/lancet; €3.09/daily FM sensor; €3804/hospitalized SHE; €1794/hospital-attended non-admitted SHE; €389/community-attended SHE). Costs were €2700 and €2120/year/patient using SMBG or FreeStyle Libre 2 system, respectively. For 1000 patients with T2DM using basal-bolus insulin, 1220 SHEs/year (with 48 hospitalizations) could be prevented and FreeSytle Libre 2 system could generate cost savings of up to €580,953/year versus SMBG (- 21.5%). FreeStyle Libre 2 system is a potential cost-saving strategy in patients with T2DM in Spain on a basal-bolus insulin regimen.