Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country

BACKGROUND: Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. OBJECTIVE: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure wate...

Descripción completa

Detalles Bibliográficos
Autores: Peña, Joaquín de la, Calderón, Ángel, Esteban, José M., López Rosés, Leopoldo, Martínez Ares, David, Nogales, Óscar, Orive Calzada, Aitor, Rodríguez Muñoz, Sarbelio, Sánchez Hernández, Eloy, Vila, Juan, Fernández Esparrach, Glòria
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2014
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/119054
Acceso en línea:https://hdl.handle.net/2445/119054
Access Level:acceso abierto
Palabra clave:Endoscòpia
Mucosa gastrointestinal
Cirurgia digestiva
Endoscopy
Gastrointestinal mucosa
Gastrointestinal surgery
Descripción
Sumario:BACKGROUND: Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. OBJECTIVE: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. MATERIAL AND METHODS: We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). RESULTS: Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). CONCLUSION: despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.