Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions
Demagnetization fault detection of in-service permanent magnet synchronous machines (PMSMs) is a challenging task, because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman fil...
| Authors: | , , , , , |
|---|---|
| Format: | article |
| Publication Date: | 2016 |
| Country: | España |
| Institution: | Universitat Politècnica de Catalunya (UPC) |
| Repository: | UPCommons. Portal del coneixement obert de la UPC |
| Language: | English |
| OAI Identifier: | oai:upcommons.upc.edu:2117/99956 |
| Online Access: | https://hdl.handle.net/2117/99956 https://dx.doi.org/10.1109/TMAG.2015.2511003 |
| Access Level: | Open access |
| Keyword: | Demagnetization fault detection nonstationary permanent magnet synchronous motors (PMSMs) Vold-Kalman filtering (VKF) MAGNET SYNCHRONOUS MOTORS PERMANENT-MAGNET MACHINES Magnetisme Electromagnetisme desmanegt Àrees temàtiques de la UPC::Enginyeria elèctrica::Dispositius magnètics Àrees temàtiques de la UPC::Física::Electromagnetisme |
| id |
ES_84c6d457cdc67e255bcb054cc2eab88c |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/99956 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditionsWang, ChaoDelgado Prieto, Miquel|||0000-0001-9282-838XRomeral Martínez, José Luis|||0000-0001-8112-8038Chen, ZheBlaabjerg, FredeLiu, XiaoyanDemagnetizationfault detectionnonstationarypermanent magnet synchronous motors (PMSMs)Vold-Kalman filtering (VKF)MAGNET SYNCHRONOUS MOTORSPERMANENT-MAGNETMACHINESMagnetismeElectromagnetismedesmanegtÀrees temàtiques de la UPC::Enginyeria elèctrica::Dispositius magnèticsÀrees temàtiques de la UPC::Física::ElectromagnetismeDemagnetization fault detection of in-service permanent magnet synchronous machines (PMSMs) is a challenging task, because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman filter is proposed to detect the partial demagnetization fault in PMSMs running at nonstationary conditions. The amplitude of envelope of the fault characteristic orders is used as fault indictor. Experimental results verify the superiority of the proposed method on the partial demagnetization online fault detection of PMSMs under various speed and load conditions.20162016-07-0120172017-01-24journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/99956https://dx.doi.org/10.1109/TMAG.2015.2511003reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/999562026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| title |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| spellingShingle |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions Wang, Chao Demagnetization fault detection nonstationary permanent magnet synchronous motors (PMSMs) Vold-Kalman filtering (VKF) MAGNET SYNCHRONOUS MOTORS PERMANENT-MAGNET MACHINES Magnetisme Electromagnetisme desmanegt Àrees temàtiques de la UPC::Enginyeria elèctrica::Dispositius magnètics Àrees temàtiques de la UPC::Física::Electromagnetisme |
| title_short |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| title_full |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| title_fullStr |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| title_full_unstemmed |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| title_sort |
Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions |
| dc.creator.none.fl_str_mv |
Wang, Chao Delgado Prieto, Miquel|||0000-0001-9282-838X Romeral Martínez, José Luis|||0000-0001-8112-8038 Chen, Zhe Blaabjerg, Frede Liu, Xiaoyan |
| author |
Wang, Chao |
| author_facet |
Wang, Chao Delgado Prieto, Miquel|||0000-0001-9282-838X Romeral Martínez, José Luis|||0000-0001-8112-8038 Chen, Zhe Blaabjerg, Frede Liu, Xiaoyan |
| author_role |
author |
| author2 |
Delgado Prieto, Miquel|||0000-0001-9282-838X Romeral Martínez, José Luis|||0000-0001-8112-8038 Chen, Zhe Blaabjerg, Frede Liu, Xiaoyan |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Demagnetization fault detection nonstationary permanent magnet synchronous motors (PMSMs) Vold-Kalman filtering (VKF) MAGNET SYNCHRONOUS MOTORS PERMANENT-MAGNET MACHINES Magnetisme Electromagnetisme desmanegt Àrees temàtiques de la UPC::Enginyeria elèctrica::Dispositius magnètics Àrees temàtiques de la UPC::Física::Electromagnetisme |
| topic |
Demagnetization fault detection nonstationary permanent magnet synchronous motors (PMSMs) Vold-Kalman filtering (VKF) MAGNET SYNCHRONOUS MOTORS PERMANENT-MAGNET MACHINES Magnetisme Electromagnetisme desmanegt Àrees temàtiques de la UPC::Enginyeria elèctrica::Dispositius magnètics Àrees temàtiques de la UPC::Física::Electromagnetisme |
| description |
Demagnetization fault detection of in-service permanent magnet synchronous machines (PMSMs) is a challenging task, because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman filter is proposed to detect the partial demagnetization fault in PMSMs running at nonstationary conditions. The amplitude of envelope of the fault characteristic orders is used as fault indictor. Experimental results verify the superiority of the proposed method on the partial demagnetization online fault detection of PMSMs under various speed and load conditions. |
| publishDate |
2016 |
| dc.date.none.fl_str_mv |
2016 2016-07-01 2017 2017-01-24 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 AM http://purl.org/coar/version/c_ab4af688f83e57aa |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/99956 https://dx.doi.org/10.1109/TMAG.2015.2511003 |
| url |
https://hdl.handle.net/2117/99956 https://dx.doi.org/10.1109/TMAG.2015.2511003 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869412249684148224 |
| score |
15,301629 |