Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions

Demagnetization fault detection of in-service permanent magnet synchronous machines (PMSMs) is a challenging task, because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman fil...

Descripción completa

Detalles Bibliográficos
Autores: Wang, Chao, Delgado Prieto, Miquel|||0000-0001-9282-838X, Romeral Martínez, José Luis|||0000-0001-8112-8038, Chen, Zhe, Blaabjerg, Frede, Liu, Xiaoyan
Tipo de recurso: artículo
Fecha de publicación:2016
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/99956
Acceso en línea:https://hdl.handle.net/2117/99956
https://dx.doi.org/10.1109/TMAG.2015.2511003
Access Level:acceso abierto
Palabra clave:Demagnetization
fault detection
nonstationary
permanent magnet synchronous motors (PMSMs)
Vold-Kalman filtering (VKF)
MAGNET SYNCHRONOUS MOTORS
PERMANENT-MAGNET
MACHINES
Magnetisme
Electromagnetisme
desmanegt
Àrees temàtiques de la UPC::Enginyeria elèctrica::Dispositius magnètics
Àrees temàtiques de la UPC::Física::Electromagnetisme
Descripción
Sumario:Demagnetization fault detection of in-service permanent magnet synchronous machines (PMSMs) is a challenging task, because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman filter is proposed to detect the partial demagnetization fault in PMSMs running at nonstationary conditions. The amplitude of envelope of the fault characteristic orders is used as fault indictor. Experimental results verify the superiority of the proposed method on the partial demagnetization online fault detection of PMSMs under various speed and load conditions.