Tear break-up time for tear film evaluation: Are moistening solutions interchangeable?

Purpose: It was the main purpose of this study to investigate the influence of the moistening solution on TBUT measurements in an asymptomatic population.; Methods: An online survey was employed to determine the compliance of Spanish eye care practitioners with the recommended normalized procedure t...

Descripción completa

Detalles Bibliográficos
Autores: Serés Revés, Carmen|||0000-0002-8333-8159, Quevedo Junyent, Luisa Jesús|||0000-0002-0976-9372, Cardona Torradeflot, Genís|||0000-0002-4770-8992, Blanch, Estel·la, Augé Serra, Montserrat
Tipo de recurso: artículo
Fecha de publicación:2015
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/79565
Acceso en línea:https://hdl.handle.net/2117/79565
https://dx.doi.org/10.1016/j.clae.2015.03.003
Access Level:acceso abierto
Palabra clave:Dry eye syndromes
Tears
Eye--Diseases
Dry eye
Moistening solution
Sodium fluorescein
Tear break-up time
Tear film
DRY EYE DISEASE
SODIUM HYALURONATE
RESIDENCE TIMES
REPEATABILITY
SUBCOMMITTEE
WORKSHOP
VALUES
TESTS
Ulls -- Malalties i defectes
Dacriologia
Àrees temàtiques de la UPC::Ciències de la visió
Descripción
Sumario:Purpose: It was the main purpose of this study to investigate the influence of the moistening solution on TBUT measurements in an asymptomatic population.; Methods: An online survey was employed to determine the compliance of Spanish eye care practitioners with the recommended normalized procedure to administer TBUT. For the purpose of examining the clinical relevance of discrepancies from the recommended procedure, a randomized, double-masked, bilateral study was designed in which a micropipette was used to moisten fluorescein strips with a controlled volume of six different solutions, commonly available in the contact lens office, and TBUT was measured in 58 non-dry eye (OSDI < 15) subjects (age from 19 to 32 years).; Results: Results from the online survey revealed that 64% of Spanish practitioners frequently use (or have used) different solutions to moisten fluorescein strips during TBUT assessment. Statistically significant differences in TBUT values were found between the various solutions as a whole (chi(2) = 198.384, p < 0.001), as well as between all solutions when explored pair-wise (all p < 0.001), except for the two saline solutions.; Conclusions: The present findings support the relevance of selecting the appropriate solution when conducting TBUT for the evaluation of the tear film. Deviations from the recommended procedure may result in misdiagnosis of dry eye and unnecessary patient referral. (C) 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.