High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene

[EN] Escherichia coli O157 (E. coli O157) is responsible for outbreaks of high morbidity in food-borne infections. The development of sensitive, reliable, and selective detection systems is of great importance in food safety. In this work, two high fundamental frequency (HFF) piezoelectric genosenso...

Descripción completa

Detalles Bibliográficos
Autores: Barrientos, Kaory, Jaramillo, Marisol, Aldrín Vásquez, Neil, ROCHA GASO, MARÍA ISABEL|||0000-0003-2949-4457
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/193142
Acceso en línea:https://riunet.upv.es/handle/10251/193142
Access Level:acceso abierto
Palabra clave:E. coli O157
Genosensor
High frequency
Quartz crystal microbalance piezoelectric
TECNOLOGIA ELECTRONICA
id ES_7d751c923c29d2bd264c006cfbf2c0b6
oai_identifier_str oai:riunet.upv.es:10251/193142
network_acronym_str ES
network_name_str España
repository_id_str
spelling High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE GeneBarrientos, KaoryJaramillo, MarisolAldrín Vásquez, NeilROCHA GASO, MARÍA ISABEL|||0000-0003-2949-4457E. coli O157GenosensorHigh frequencyQuartz crystal microbalance piezoelectricTECNOLOGIA ELECTRONICA[EN] Escherichia coli O157 (E. coli O157) is responsible for outbreaks of high morbidity in food-borne infections. The development of sensitive, reliable, and selective detection systems is of great importance in food safety. In this work, two high fundamental frequency (HFF) piezoelectric genosensors (100 and 150 MHz) were designed and validated for the rfbE gene detection, which encodes O-antigen in E. coli O157. HFF resonators offer improved sensitivity, small sample volumes, and the possibility of integration into lab-on-a-chip devices, but their sensing capabilities have not yet been fully explored. This HFF-QCM genosensor uses the method of physisorption based on the union between the streptavidin and the biotin to immobilize the genetic bioreceptor on the surface and detect its hybridization with the target sequence. Parameters such as molecular coating, specificity, and variability were tested to enhance its performance. Although both genosensors evaluated are able to determine the target, the 100 MHz device has a higher response to the analyte than the 150 MHz platform. This is the first step in the development of an HFF-QCM genosensor that may be used as a trial test of E. coli O157 in large batches of samples.This work was supported by the EIA University and the National University of Colombia under internal call in 2016.Taylor & FrancisDepartamento de Ingeniería ElectrónicaEscuela Técnica Superior de Ingeniería Aeroespacial y Diseño IndustrialCentro de Investigación e Innovación en BioingenieríaUniversidad Nacional de ColombiaRepositorio Institucional de la Universitat Politècnica de València Riunet20222022-09-13journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://riunet.upv.es/handle/10251/193142reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento - No comercial (by-nc) http://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1931422026-06-13T07:49:27Z
dc.title.none.fl_str_mv High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
title High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
spellingShingle High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
Barrientos, Kaory
E. coli O157
Genosensor
High frequency
Quartz crystal microbalance piezoelectric
TECNOLOGIA ELECTRONICA
title_short High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
title_full High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
title_fullStr High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
title_full_unstemmed High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
title_sort High Frequency (100, 150 MHz) Quartz Crystal Microbalance (QCM) Piezoelectric Genosensor for the Determination of the Escherichia coli O157 rfbE Gene
dc.creator.none.fl_str_mv Barrientos, Kaory
Jaramillo, Marisol
Aldrín Vásquez, Neil
ROCHA GASO, MARÍA ISABEL|||0000-0003-2949-4457
author Barrientos, Kaory
author_facet Barrientos, Kaory
Jaramillo, Marisol
Aldrín Vásquez, Neil
ROCHA GASO, MARÍA ISABEL|||0000-0003-2949-4457
author_role author
author2 Jaramillo, Marisol
Aldrín Vásquez, Neil
ROCHA GASO, MARÍA ISABEL|||0000-0003-2949-4457
author2_role author
author
author
dc.contributor.none.fl_str_mv Departamento de Ingeniería Electrónica
Escuela Técnica Superior de Ingeniería Aeroespacial y Diseño Industrial
Centro de Investigación e Innovación en Bioingeniería
Universidad Nacional de Colombia
Repositorio Institucional de la Universitat Politècnica de València Riunet
dc.subject.none.fl_str_mv E. coli O157
Genosensor
High frequency
Quartz crystal microbalance piezoelectric
TECNOLOGIA ELECTRONICA
topic E. coli O157
Genosensor
High frequency
Quartz crystal microbalance piezoelectric
TECNOLOGIA ELECTRONICA
description [EN] Escherichia coli O157 (E. coli O157) is responsible for outbreaks of high morbidity in food-borne infections. The development of sensitive, reliable, and selective detection systems is of great importance in food safety. In this work, two high fundamental frequency (HFF) piezoelectric genosensors (100 and 150 MHz) were designed and validated for the rfbE gene detection, which encodes O-antigen in E. coli O157. HFF resonators offer improved sensitivity, small sample volumes, and the possibility of integration into lab-on-a-chip devices, but their sensing capabilities have not yet been fully explored. This HFF-QCM genosensor uses the method of physisorption based on the union between the streptavidin and the biotin to immobilize the genetic bioreceptor on the surface and detect its hybridization with the target sequence. Parameters such as molecular coating, specificity, and variability were tested to enhance its performance. Although both genosensors evaluated are able to determine the target, the 100 MHz device has a higher response to the analyte than the 150 MHz platform. This is the first step in the development of an HFF-QCM genosensor that may be used as a trial test of E. coli O157 in large batches of samples.
publishDate 2022
dc.date.none.fl_str_mv 2022
2022-09-13
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://riunet.upv.es/handle/10251/193142
url https://riunet.upv.es/handle/10251/193142
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reconocimiento - No comercial (by-nc)
http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reconocimiento - No comercial (by-nc)
http://creativecommons.org/licenses/by-nc/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
instname:Universitat Politècnica de València (UPV)
instname_str Universitat Politècnica de València (UPV)
reponame_str RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
collection RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869411664872341504
score 15.300719