A three-dimensional model to describe complete human corneal oxygenation during contact lens wear

[EN] We perform a novel 3D study to quantify the corneal oxygen consumption and diffusion in each part of the cornea with different contact lens materials. The oxygen profile is calculated as a function of oxygen tension at the cornea-tear interface and the oxygen transmissibility of the lens, with...

Descripción completa

Detalles Bibliográficos
Autores: Aguilella-Arzo, Marcel, Compañ Moreno, Vicente|||0000-0001-8233-7472
Tipo de recurso: artículo
Fecha de publicación:2023
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/199007
Acceso en línea:https://riunet.upv.es/handle/10251/199007
Access Level:acceso abierto
Palabra clave:3-D model
Corneal oxygen distribution
Corneal oxygen flux
Monod kinetics model
Oxygen tension
Soft contact lens
Descripción
Sumario:[EN] We perform a novel 3D study to quantify the corneal oxygen consumption and diffusion in each part of the cornea with different contact lens materials. The oxygen profile is calculated as a function of oxygen tension at the cornea-tear interface and the oxygen transmissibility of the lens, with values used in previous studies. We aim to determine the influence of a detailed geometry of the cornea in their modeling compared to previous low dimensional models used in the literature. To this end, a 3-D study based on an axisymmetric volume element analysis model was applied to different contact lenses currently on the market. We have obtained that the model provides a valuable tool for understanding the flux and cornea oxygen profiles through the epithelium, stroma, and endothelium. The most important results are related to the dependence of the oxygen flux through the cornea-lens system on the contact lens thickness and geometry. Both parameters play an important role in the corneal flux and oxygen tension distribution. The decline in oxygen consumption experienced by the cornea takes place just inside the epithelium, where the oxygen tension falls to between 95 and 16 mmHg under open eye conditions, and 30 to 0.3 mmHg under closed eye conditions, depending on the contact lens worn. This helps to understand the physiological response of the corneal tissue under conditions of daily and overnight contact lens wear, and the importance of detailed geometry of the cornea in the modeling of diffusion for oxygen and other species.