Diffusion and Monod kinetics model to determine in vivo human corneal oxygen-consumption rate during soft contact lens wear

PURPOSE: We present an analysis of the corneal oxygen consumption Qc from non-linear models, using data of oxygen partial pressure or tension (P(O2) ) obtained from in vivo estimation previously reported by other authors. (1) METHODS: Assuming that the cornea is a single homogeneous layer, the oxyge...

Full description

Bibliographic Details
Authors: Del Castillo, Luis Felipe, Ferreira da Silva, Ana R., Hernández, Saúl Iván, Aguiella-Arzo, Marcelo, Balado, Andreu, Mollá Romano, Sergio, Compañ Moreno, Vicente|||0000-0001-8233-7472
Format: article
Publication Date:2015
Country:España
Institution:Universitat Politècnica de València (UPV)
Repository:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Language:English
OAI Identifier:oai:riunet.upv.es:10251/71218
Online Access:https://riunet.upv.es/handle/10251/71218
Access Level:Open access
Keyword:Consumo de oxigeno de la cornea
Corneal oxygen consumption
Corneal oxygen permeability
Corneal oxygen pressure
Monod kinetics model
modelo cinetico de Monod
permeabilidad al oxigeno de la cornea
presion del oxigeno en la cornea
MAQUINAS Y MOTORES TERMICOS
FISICA APLICADA
Description
Summary:PURPOSE: We present an analysis of the corneal oxygen consumption Qc from non-linear models, using data of oxygen partial pressure or tension (P(O2) ) obtained from in vivo estimation previously reported by other authors. (1) METHODS: Assuming that the cornea is a single homogeneous layer, the oxygen permeability through the cornea will be the same regardless of the type of lens that is available on it. The obtention of the real value of the maximum oxygen consumption rate Qc,max is very important because this parameter is directly related with the gradient pressure profile into the cornea and moreover, the real corneal oxygen consumption is influenced by both anterior and posterior oxygen fluxes. RESULTS: Our calculations give different values for the maximum oxygen consumption rate Qc,max, when different oxygen pressure values (high and low P(O2)) are considered at the interface cornea-tears film. CONCLUSION: Present results are relevant for the calculation on the partial pressure of oxygen, available at different depths into the corneal tissue behind contact lenses of different oxygen transmissibility.