Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users

Purpose: The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods: CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 1...

Descripción completa

Detalles Bibliográficos
Autores: Pastor-Zaplana, José Ángel, Gallar, Juana, Acosta Boj, Maria Carmen
Tipo de recurso: artículo
Fecha de publicación:2023
País:España
Institución:Universidad Miguel Hernández de Elche
Repositorio:REDIUMH. Depósito Digital de la UMH
OAI Identifier:oai:dspace.umh.es:11000/38123
Acceso en línea:https://hdl.handle.net/11000/38123
Access Level:acceso abierto
Palabra clave:contact lenses
corneal sensitivity
corneal sensory nerves
id ES_79cbfcefe4e0cbec5a93fb3468e38926
oai_identifier_str oai:dspace.umh.es:11000/38123
network_acronym_str ES
network_name_str España
repository_id_str
spelling Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic UsersPastor-Zaplana, José ÁngelGallar, JuanaAcosta Boj, Maria Carmencontact lensescorneal sensitivitycorneal sensory nervesPurpose: The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods: CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results: Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions: Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.IOVSDepartamentos de la UMH::Patología y CirugíaDepartamentos de la UMH::FisiologíaInstitutos de la UMH::Instituto de Neurociencias202520252023info:eu-repo/semantics/articleapplication/pdf9application/pdfhttps://hdl.handle.net/11000/38123reponame:REDIUMH. Depósito Digital de la UMHinstname:Universidad Miguel Hernández de ElcheInglés10.1167/iovs.64.14.12info:eu-repo/semantics/openAccessAttribution-NonCommercial-NoDerivatives 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc-nd/4.0/oai:dspace.umh.es:11000/381232026-05-27T13:36:21Z
dc.title.none.fl_str_mv Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
title Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
spellingShingle Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
Pastor-Zaplana, José Ángel
contact lenses
corneal sensitivity
corneal sensory nerves
title_short Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
title_full Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
title_fullStr Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
title_full_unstemmed Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
title_sort Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
dc.creator.none.fl_str_mv Pastor-Zaplana, José Ángel
Gallar, Juana
Acosta Boj, Maria Carmen
author Pastor-Zaplana, José Ángel
author_facet Pastor-Zaplana, José Ángel
Gallar, Juana
Acosta Boj, Maria Carmen
author_role author
author2 Gallar, Juana
Acosta Boj, Maria Carmen
author2_role author
author
dc.contributor.none.fl_str_mv Departamentos de la UMH::Patología y Cirugía
Departamentos de la UMH::Fisiología
Institutos de la UMH::Instituto de Neurociencias
dc.subject.none.fl_str_mv contact lenses
corneal sensitivity
corneal sensory nerves
topic contact lenses
corneal sensitivity
corneal sensory nerves
description Purpose: The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods: CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results: Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions: Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.
publishDate 2023
dc.date.none.fl_str_mv 2023
2025
2025
dc.type.none.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/11000/38123
url https://hdl.handle.net/11000/38123
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv 10.1167/iovs.64.14.12
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 Internacional
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.format.none.fl_str_mv application/pdf
9
application/pdf
dc.publisher.none.fl_str_mv IOVS
publisher.none.fl_str_mv IOVS
dc.source.none.fl_str_mv reponame:REDIUMH. Depósito Digital de la UMH
instname:Universidad Miguel Hernández de Elche
instname_str Universidad Miguel Hernández de Elche
reponame_str REDIUMH. Depósito Digital de la UMH
collection REDIUMH. Depósito Digital de la UMH
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869411389162913792
score 15.811543