Gamma spectrometry and LabSOCS-calculated efficiency in the radiological characterisation of quadrangular and cubic specimens of hardened portland cement paste

Pursuant to European Directive 2013/59, materials additioned with NORM waste must be characterised radiologically to determine their acceptability for use in construction. The radionuclides studied to judge that acceptability, 232Th, 226Ra and 40K, are normally measured with gamma spectrometry. Gamm...

Full description

Bibliographic Details
Authors: Suárez-Navarro, José Antonio, Moreno de los Reyes, A.M., Gascó, C., Alonso López, M. del Mar, Puertas, Francisca
Format: article
Status:Versión aceptada para publicación
Publication Date:2020
Country:España
Institution:Consejo Superior de Investigaciones Científicas (CSIC)
Repository:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/219478
Online Access:http://hdl.handle.net/10261/219478
Access Level:Open access
Keyword:NORMs
Efficiency calibration
Cement
Gamma spectrometry
LabSOCS
Description
Summary:Pursuant to European Directive 2013/59, materials additioned with NORM waste must be characterised radiologically to determine their acceptability for use in construction. The radionuclides studied to judge that acceptability, 232Th, 226Ra and 40K, are normally measured with gamma spectrometry. Gamma detectors are calibrated by using standards as similar as possible in dimensions and chemical composition as the matrix in the samples to be measured. In light of the broad spectrum of chemical and physical characteristics of NORM samples, experimental calibration is often beyond the means of gamma spectrometry laboratories. As a result, Monte Carlo-based methods are deployed to simulate the experimental setup consisting in detector and sample, both geometrically and chemically. Canberra Industries’ LabSOCS (Laboratory Sourceless Calibration Software) is one of the tools available for such calculations. This study verified the accuracy and precision of the counting efficiency delivered by LabSOCS, both with the standard powder geometry and a new geometry consisting in a 5 cm cubic specimen of Portland cement paste. The findings showed that in both geometries the accuracy and precision of LabSOCS-calculated efficiency (by specimen height and activity), across an energy range from 45.64 keV (210Pb) to 1460.82 keV (40K) met the acceptability criteria routinely applied in environmental radioactivity laboratories. The geometry proposed yielded activity values for the end construction material closer to the true indices than the conventional method consisting in summing the partial activities of the unreacted components.