A simple immunoassay for extracellular vesicle liquid biopsy in microliters of non‑processed plasma

Background: Extracellular vesicles (EVs), released by most cell types, provide an excellent source of biomarkers in biological fuids. However, in order to perform validation studies and screenings of patient samples, it is still necessary to develop general techniques permitting rapid handling of sm...

Descripción completa

Detalles Bibliográficos
Autores: Campos-Silva, Carmen, Cáceres-Martell, Yaiza, Sánchez‑Herrero, Estela, Sandúa, Amaia, Beneítez-Martínez, Alexandra, González, Álvaro, Provencio, Mariano, Romero, Atocha, Jara-Acevedo, Ricardo, Yáñez-Mó, María, Valés-Gómez, Mar
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad Loyola Andalucía
Repositorio:Brújula
OAI Identifier:oai:repositorio.uloyola.es:20.500.12412/5659
Acceso en línea:https://hdl.handle.net/20.500.12412/5659
Access Level:acceso abierto
Palabra clave:Extracellular vesicles
Cancer
Colloids
Flocculation
ELISA
Flow cytometry
Liquid biopsy
Descripción
Sumario:Background: Extracellular vesicles (EVs), released by most cell types, provide an excellent source of biomarkers in biological fuids. However, in order to perform validation studies and screenings of patient samples, it is still necessary to develop general techniques permitting rapid handling of small amounts of biological samples from large numbers of donors. Results: Here we describe a method that, using just a few microliters of patient’s plasma, identifes tumour markers exposed on EVs. Studying physico-chemical properties of EVs in solution, we demonstrate that they behave as stable colloidal suspensions and therefore, in immunocapture assays, many of them are unable to interact with a stationary functionalised surface. Using focculation methods, like those used to destabilize colloids, we demonstrate that cationic polymers increase EV ζ-potential, diameter, and sedimentation coefcient and thus, allow a more efcient capture on antibody-coated surfaces by both ELISA and bead-assisted fow cytometry. These fndings led to optimization of a protocol in microtiter plates allowing efective immunocapture of EVs, directly in plasma without previous ultracentrifugation or other EV enrichment. The method, easily adaptable to any laboratory, has been validated using plasma from lung cancer patients in which the epithelial cell marker EpCAM has been detected on EVs. Conclusions: This optimized high throughput, easy to automate, technology allows screening of large numbers of patients to phenotype tumour markers in circulating EVs, breaking barriers for the validation of proposed EV biomarkers and the discovery of new ones.