Development of an electrochemical sensor for coeliac disease serological markers
Coeliac disease (CD), a gluten-sensitive enteropathy, is an autoimmune disorder of the upper small intestine triggered from the gluten ingestion (cereal protein found in wheat, rye and barley) and affects 1% of the population around the globe. The ingestion of gluten, triggers the production of a se...
| Autor: | |
|---|---|
| Tipo de recurso: | tesis doctoral |
| Estado: | Versión publicada |
| Fecha de publicación: | 2012 |
| País: | España |
| Institución: | Universitat Rovira i virgili (URV) |
| Repositorio: | Repositori Institucional de la Universitat Rovira i Virgili |
| OAI Identifier: | oai:urv.cat:TDX:1138 |
| Acceso en línea: | https://hdl.handle.net/20.500.11797/TDX1138 http://hdl.handle.net/10803/96661 |
| Access Level: | acceso abierto |
| Palabra clave: | 62 - Enginyeria. Tecnologia 577 - Bioquímica. Biologia molecular. Biofísica 543 - Química analítica |
| id |
ES_77efeba51968c65489bb4ff08d4955cf |
|---|---|
| oai_identifier_str |
oai:urv.cat:TDX:1138 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| dc.title.none.fl_str_mv |
Development of an electrochemical sensor for coeliac disease serological markers |
| title |
Development of an electrochemical sensor for coeliac disease serological markers |
| spellingShingle |
Development of an electrochemical sensor for coeliac disease serological markers Rosales Rivera, Luis Carlos 62 - Enginyeria. Tecnologia 577 - Bioquímica. Biologia molecular. Biofísica 543 - Química analítica |
| title_short |
Development of an electrochemical sensor for coeliac disease serological markers |
| title_full |
Development of an electrochemical sensor for coeliac disease serological markers |
| title_fullStr |
Development of an electrochemical sensor for coeliac disease serological markers |
| title_full_unstemmed |
Development of an electrochemical sensor for coeliac disease serological markers |
| title_sort |
Development of an electrochemical sensor for coeliac disease serological markers |
| dc.creator.none.fl_str_mv |
Rosales Rivera, Luis Carlos |
| author |
Rosales Rivera, Luis Carlos |
| author_facet |
Rosales Rivera, Luis Carlos |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Departament d'Enginyeria Química Universitat Rovira i Virgili. |
| dc.subject.none.fl_str_mv |
62 - Enginyeria. Tecnologia 577 - Bioquímica. Biologia molecular. Biofísica 543 - Química analítica |
| topic |
62 - Enginyeria. Tecnologia 577 - Bioquímica. Biologia molecular. Biofísica 543 - Química analítica |
| description |
Coeliac disease (CD), a gluten-sensitive enteropathy, is an autoimmune disorder of the upper small intestine triggered from the gluten ingestion (cereal protein found in wheat, rye and barley) and affects 1% of the population around the globe. The ingestion of gluten, triggers the production of a series of autoantibodies against gliadin (AGA) and tissue transglutaminase (anti-tTG) which can provoke inflammation and damage some parts of the intestine. The detection of those antibodies through serological testing represent a non-invasive, fast and reliable approach. The main objective of this Thesis is the development of a sensitive, rapid and cost-efficient real-sample-oriented immunosensor using thiol-self assembled monolayers on gold surfaces. Two strategies for the antigen immobilisation have been investigated: i) The use of monolayers of a carboxylic acid-ended bipodal alkanethiol, ii) The introduction of disulfide groups through three different moieties of the antigens: amine, carboxylic and hydroxyl. Both immunosensor approaches were optimized and used for the amperometric detection of CD serological markers from human serum samples. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis |
| format |
doctoralThesis |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/20.500.11797/TDX1138 http://hdl.handle.net/10803/96661 |
| url |
https://hdl.handle.net/20.500.11797/TDX1138 http://hdl.handle.net/10803/96661 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf 148 p. |
| dc.publisher.none.fl_str_mv |
Universitat Rovira i Virgili |
| publisher.none.fl_str_mv |
Universitat Rovira i Virgili |
| dc.source.none.fl_str_mv |
reponame:Repositori Institucional de la Universitat Rovira i Virgili instname:Universitat Rovira i virgili (URV) |
| instname_str |
Universitat Rovira i virgili (URV) |
| reponame_str |
Repositori Institucional de la Universitat Rovira i Virgili |
| collection |
Repositori Institucional de la Universitat Rovira i Virgili |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869411158823272448 |
| spelling |
Development of an electrochemical sensor for coeliac disease serological markersRosales Rivera, Luis Carlos62 - Enginyeria. Tecnologia577 - Bioquímica. Biologia molecular. Biofísica543 - Química analíticaCoeliac disease (CD), a gluten-sensitive enteropathy, is an autoimmune disorder of the upper small intestine triggered from the gluten ingestion (cereal protein found in wheat, rye and barley) and affects 1% of the population around the globe. The ingestion of gluten, triggers the production of a series of autoantibodies against gliadin (AGA) and tissue transglutaminase (anti-tTG) which can provoke inflammation and damage some parts of the intestine. The detection of those antibodies through serological testing represent a non-invasive, fast and reliable approach. The main objective of this Thesis is the development of a sensitive, rapid and cost-efficient real-sample-oriented immunosensor using thiol-self assembled monolayers on gold surfaces. Two strategies for the antigen immobilisation have been investigated: i) The use of monolayers of a carboxylic acid-ended bipodal alkanethiol, ii) The introduction of disulfide groups through three different moieties of the antigens: amine, carboxylic and hydroxyl. Both immunosensor approaches were optimized and used for the amperometric detection of CD serological markers from human serum samples.La celiaquía, intolerancia al gluten, es una enfermedad autoinmune que afecta principalmente a la parte próxima del intestino delgado y que está presente en el 1% de la población mundial. La ingestión de gluten (proteína presente en el trigo, la cebada, el centeno) desencadena la producción de anticuerpos anti-gliadina (AGA) y anti-transglutaminasa tisular (anti-tTG) que pueden provocar inflamación y daños en el intestino delgado. La detección de estos anticuerpos mediante el uso de pruebas serológicas representa una alternativa rápida, confiable y no invasiva. El objetivo principal de esta Tesis es el desarrollo de inmunosensores usando monocapas de tioles autoensambladas en superficies de oro que sean rápidos, sensibles y de bajo coste, pero eficientes para su uso en muestras reales. Dos estrategias para inmovilizar los antígenos fueron exploradas: i) Usando monocapas autoensambladas de un alcanotiol bípedo, que posee grupos carboxílicos, ii) Introduciendo grupos disulfuro a través de los distintos grupos presentes en los antígenos: carboxílicos, aminos e hidroxilos. Ambas estrategias para construir los inmunosensores fueron optimizadas y usadas para la detección amperométrica de los marcadores serológicos de la celiaquía en muestras humanas de suero.Universitat Rovira i Virgili Departament d'Enginyeria QuímicaUniversitat Rovira i Virgili.2012info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf148 p.https://hdl.handle.net/20.500.11797/TDX1138http://hdl.handle.net/10803/96661reponame:Repositori Institucional de la Universitat Rovira i Virgiliinstname:Universitat Rovira i virgili (URV)Inglésinfo:eu-repo/semantics/openAccessADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al repositori institucional de la Universitat Rovira i Virgili. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a aquest repositori (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.oai:urv.cat:TDX:11382026-06-23T12:42:27Z |
| score |
15,300724 |