Two tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests. Forty-nine adults participated in the study. Participants’ negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured obj...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2023 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/387722 |
| Acceso en línea: | https://hdl.handle.net/2117/387722 https://dx.doi.org/10.1371/journal.pone.0284552 |
| Access Level: | acceso abierto |
| Palabra clave: | Eye -- Movements Binocular vision Ulls -- Moviments Visió binocular Àrees temàtiques de la UPC::Ciències de la visió |
| id |
ES_5bd13641b532ae5461bd5218005a4ecc |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/387722 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Feasibility of measuring fusional vergence amplitudes objectivelyRovira Gay, Cristina|||0000-0001-9765-1691Mestre Ferrer, Clara|||0000-0003-0053-550XArgilés Sans, Marc|||0000-0001-5474-9832Viñuela Navarro, Valldeflors|||0000-0002-1933-5906Pujol Ramo, Jaume|||0000-0003-0811-9244Eye -- MovementsBinocular visionUlls -- MovimentsVisió binocularÀrees temàtiques de la UPC::Ciències de la visióTwo tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests. Forty-nine adults participated in the study. Participants’ negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured objectively in an haploscopic set-up by recording eye movements with an EyeLink 1000 Plus (SR Research). Stimulus disparity changed in steps or smoothly mimicking a prim bar and a Risley prism, respectively. Break and recovery points were determined offline using a custom Matlab algorithm for the analysis of eye movements. Fusional vergence amplitudes were also measured with two clinical tests using a Risley prism and a prism bar. A better agreement between tests was found for the measurement of BI than for BO fusional vergence amplitudes. The means ± SD of the differences between the BI break and recovery points measured with the two objective tests were -1.74 ± 3.35 PD and -1.97 ± 2.60 PD, respectively, which were comparable to those obtained for the subjective tests. For the BO break and recovery points, although the means of the differences between the two objective tests were small, high variability between subjects was found (0.31 ± 6.44 PD and -2.84 ± 7.01 PD, respectively). This study showed the feasibility to measure fusional vergence amplitudes objectively and overcome limitations of the conventional subjective tests. However, these tests cannot be used interchangeably due to their poor agreement.This study is part of the project PID2020-112527RB-I00, funded by MCIN/AEI/10.13039/501100011033. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.Peer ReviewedPublic Library of Science (PLOS)20232023-05-0420232023-05-23journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/387722https://dx.doi.org/10.1371/journal.pone.0284552reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)InglésengAgencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-112527RB-I00 FOTONICA BIOMEDICA Y MACHINE LEARNING PARA EL DIAGNOSTICO Y TRATAMIENTO DE DISFUNCIONES OCULARES, DETERIORO COGNITIVO Y ENFERMEDADES HEMATOLOGICASopen accesshttp://purl.org/coar/access_right/c_abf2Attribution 4.0 Internationalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/3877222026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Feasibility of measuring fusional vergence amplitudes objectively |
| title |
Feasibility of measuring fusional vergence amplitudes objectively |
| spellingShingle |
Feasibility of measuring fusional vergence amplitudes objectively Rovira Gay, Cristina|||0000-0001-9765-1691 Eye -- Movements Binocular vision Ulls -- Moviments Visió binocular Àrees temàtiques de la UPC::Ciències de la visió |
| title_short |
Feasibility of measuring fusional vergence amplitudes objectively |
| title_full |
Feasibility of measuring fusional vergence amplitudes objectively |
| title_fullStr |
Feasibility of measuring fusional vergence amplitudes objectively |
| title_full_unstemmed |
Feasibility of measuring fusional vergence amplitudes objectively |
| title_sort |
Feasibility of measuring fusional vergence amplitudes objectively |
| dc.creator.none.fl_str_mv |
Rovira Gay, Cristina|||0000-0001-9765-1691 Mestre Ferrer, Clara|||0000-0003-0053-550X Argilés Sans, Marc|||0000-0001-5474-9832 Viñuela Navarro, Valldeflors|||0000-0002-1933-5906 Pujol Ramo, Jaume|||0000-0003-0811-9244 |
| author |
Rovira Gay, Cristina|||0000-0001-9765-1691 |
| author_facet |
Rovira Gay, Cristina|||0000-0001-9765-1691 Mestre Ferrer, Clara|||0000-0003-0053-550X Argilés Sans, Marc|||0000-0001-5474-9832 Viñuela Navarro, Valldeflors|||0000-0002-1933-5906 Pujol Ramo, Jaume|||0000-0003-0811-9244 |
| author_role |
author |
| author2 |
Mestre Ferrer, Clara|||0000-0003-0053-550X Argilés Sans, Marc|||0000-0001-5474-9832 Viñuela Navarro, Valldeflors|||0000-0002-1933-5906 Pujol Ramo, Jaume|||0000-0003-0811-9244 |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Eye -- Movements Binocular vision Ulls -- Moviments Visió binocular Àrees temàtiques de la UPC::Ciències de la visió |
| topic |
Eye -- Movements Binocular vision Ulls -- Moviments Visió binocular Àrees temàtiques de la UPC::Ciències de la visió |
| description |
Two tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests. Forty-nine adults participated in the study. Participants’ negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured objectively in an haploscopic set-up by recording eye movements with an EyeLink 1000 Plus (SR Research). Stimulus disparity changed in steps or smoothly mimicking a prim bar and a Risley prism, respectively. Break and recovery points were determined offline using a custom Matlab algorithm for the analysis of eye movements. Fusional vergence amplitudes were also measured with two clinical tests using a Risley prism and a prism bar. A better agreement between tests was found for the measurement of BI than for BO fusional vergence amplitudes. The means ± SD of the differences between the BI break and recovery points measured with the two objective tests were -1.74 ± 3.35 PD and -1.97 ± 2.60 PD, respectively, which were comparable to those obtained for the subjective tests. For the BO break and recovery points, although the means of the differences between the two objective tests were small, high variability between subjects was found (0.31 ± 6.44 PD and -2.84 ± 7.01 PD, respectively). This study showed the feasibility to measure fusional vergence amplitudes objectively and overcome limitations of the conventional subjective tests. However, these tests cannot be used interchangeably due to their poor agreement. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2023 2023-05-04 2023 2023-05-23 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/387722 https://dx.doi.org/10.1371/journal.pone.0284552 |
| url |
https://hdl.handle.net/2117/387722 https://dx.doi.org/10.1371/journal.pone.0284552 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Agencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-112527RB-I00 FOTONICA BIOMEDICA Y MACHINE LEARNING PARA EL DIAGNOSTICO Y TRATAMIENTO DE DISFUNCIONES OCULARES, DETERIORO COGNITIVO Y ENFERMEDADES HEMATOLOGICAS |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Public Library of Science (PLOS) |
| publisher.none.fl_str_mv |
Public Library of Science (PLOS) |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869408841023619072 |
| score |
15,300724 |