Analysis of saccade characteristics during fusional vergence tests in normal binocular vision participants

The purpose of the study was to analyze, characterize, and compare the measurements of saccades that occurred during the positive and negative fusional vergence test (PFV and NFV, respectively) as a function of the disparity vergence demand. Thirty-four participants’ PFV and NFV amplitudes were meas...

Descripción completa

Detalles Bibliográficos
Autores: Rovira Gay, Cristina|||0000-0001-9765-1691, Mestre Ferrer, Clara|||0000-0003-0053-550X, Argilés Sans, Marc|||0000-0001-5474-9832, Pujol Ramo, Jaume|||0000-0003-0811-9244
Tipo de recurso: artículo
Fecha de publicación:2026
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/452758
Acceso en línea:https://hdl.handle.net/2117/452758
https://dx.doi.org/10.3390/jemr19010015
Access Level:acceso abierto
Palabra clave:Binocular vision
Fusional vergence
Eye tracking
Saccades detection
Àrees temàtiques de la UPC::Ciències de la visió::Optometria::Visió binocular
Descripción
Sumario:The purpose of the study was to analyze, characterize, and compare the measurements of saccades that occurred during the positive and negative fusional vergence test (PFV and NFV, respectively) as a function of the disparity vergence demand. Thirty-four participants’ PFV and NFV amplitudes were measured in a haploscopic setup, recording eye movements with an Eyelink 1000 Plus (SR Research). The visual stimulus was a column of letters. Break and recovery points were determined objectively offline, and saccades were detected with a velocity-threshold-based method. A total of 13,103 and 14,381 saccades were detected during the measurement of the PFV and NFV ranges, respectively. Saccades followed the main sequence (¿ = 0.97, p < 0.001). The distributions of saccadic amplitudes during PFV and NFV differed significantly (U = 4.28, p < 0.001). The amplitude of saccades that occurred while fusion was maintained (median (IQR) 0.73 (0.92) deg) was significantly smaller than that of saccades during diplopia (2.10 (3.90) deg) (U = -75.63, p < 0.001). The distributions of saccade direction during the measurement of PFV and NFV amplitudes were statistically significantly different (p < 0.01). These findings contribute to a better understanding of how the visual system adjusts saccades in response to different disparity vergence demand during fusional vergence amplitudes evaluation.