Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses

PURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri...

Descripción completa

Detalles Bibliográficos
Autores: Vega, F, Alba-Bueno, F, Millan, MS, Varon, C, Gil, MA, Buil, JA
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2015
País:España
Institución:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
Repositorio:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
OAI Identifier:oai:iibsantpau.fundanetsuite.com:p14506
Acceso en línea:https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=14506
Access Level:acceso abierto
Palabra clave:cataract surgery
diffractive bifocal intraocular lens
diffractive trifocal intraocular lens
halo
through-focus performance
id ES_590b8cedbbc1c6327c0dc4acd45ee1bc
oai_identifier_str oai:iibsantpau.fundanetsuite.com:p14506
network_acronym_str ES
network_name_str España
repository_id_str
spelling Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular LensesVega, FAlba-Bueno, FMillan, MSVaron, CGil, MABuil, JAcataract surgerydiffractive bifocal intraocular lensdiffractive trifocal intraocular lenshalothrough-focus performancePURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standardization eye model. The modulation transfer function (MTF) at the IOLs' foci was obtained with pupils ranging from 2.0 to 5.0 mm. Through-focus MTF curves (at 50 cycles/mm) were compared among all the IOLs. The halo formation and characteristics were obtained from image analysis. RESULTS. The multifocal IOLs studied in this work showed, at their foci, secondary out-of-focus images, which originate halos and whose characteristics depend on the lens design and pupil size. The smallest halo occurred for the distance focus of the SV25T0. The distance and near foci of the SV25T0 yielded, respectively, the best and lowest optical quality among the studied IOLs. The distance focus of the ZKB00, AT LISA, and AT LISA tri were of similar quality, but the near focus of the ZKB00 outperformed the near foci of the rest of the IOLs. The IOLs' optical performance gradually deteriorates as pupil increases. CONCLUSIONS. Differences in the design of the diffractive IOLs translate into differences in optical quality at their foci, through-focus performance, and halo features, which can offer further information to surgeons when selecting which IOL to implant.ASSOC RESEARCH VISION OPHTHALMOLOGY INC2015info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=14506INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCEISSN: 01460404ISSNe: 15525783reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pauinstname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)Inglésinfo:eu-repo/semantics/openAccessoai:iibsantpau.fundanetsuite.com:p145062026-06-14T12:41:47Z
dc.title.none.fl_str_mv Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
title Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
spellingShingle Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
Vega, F
cataract surgery
diffractive bifocal intraocular lens
diffractive trifocal intraocular lens
halo
through-focus performance
title_short Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
title_full Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
title_fullStr Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
title_full_unstemmed Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
title_sort Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses
dc.creator.none.fl_str_mv Vega, F
Alba-Bueno, F
Millan, MS
Varon, C
Gil, MA
Buil, JA
author Vega, F
author_facet Vega, F
Alba-Bueno, F
Millan, MS
Varon, C
Gil, MA
Buil, JA
author_role author
author2 Alba-Bueno, F
Millan, MS
Varon, C
Gil, MA
Buil, JA
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv cataract surgery
diffractive bifocal intraocular lens
diffractive trifocal intraocular lens
halo
through-focus performance
topic cataract surgery
diffractive bifocal intraocular lens
diffractive trifocal intraocular lens
halo
through-focus performance
description PURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standardization eye model. The modulation transfer function (MTF) at the IOLs' foci was obtained with pupils ranging from 2.0 to 5.0 mm. Through-focus MTF curves (at 50 cycles/mm) were compared among all the IOLs. The halo formation and characteristics were obtained from image analysis. RESULTS. The multifocal IOLs studied in this work showed, at their foci, secondary out-of-focus images, which originate halos and whose characteristics depend on the lens design and pupil size. The smallest halo occurred for the distance focus of the SV25T0. The distance and near foci of the SV25T0 yielded, respectively, the best and lowest optical quality among the studied IOLs. The distance focus of the ZKB00, AT LISA, and AT LISA tri were of similar quality, but the near focus of the ZKB00 outperformed the near foci of the rest of the IOLs. The IOLs' optical performance gradually deteriorates as pupil increases. CONCLUSIONS. Differences in the design of the diffractive IOLs translate into differences in optical quality at their foci, through-focus performance, and halo features, which can offer further information to surgeons when selecting which IOL to implant.
publishDate 2015
dc.date.none.fl_str_mv 2015
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=14506
url https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=14506
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv ASSOC RESEARCH VISION OPHTHALMOLOGY INC
publisher.none.fl_str_mv ASSOC RESEARCH VISION OPHTHALMOLOGY INC
dc.source.none.fl_str_mv INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
ISSN: 01460404
ISSNe: 15525783
reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
instname_str Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
reponame_str r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
collection r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869408586675781632
score 15.811543