Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses

PURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri...

Descripción completa

Detalles Bibliográficos
Autores: Vega, F, Alba-Bueno, F, Millan, MS, Varon, C, Gil, MA, Buil, JA
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2015
País:España
Institución:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
Repositorio:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
OAI Identifier:oai:iibsantpau.fundanetsuite.com:p14506
Acceso en línea:https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=14506
Access Level:acceso abierto
Palabra clave:cataract surgery
diffractive bifocal intraocular lens
diffractive trifocal intraocular lens
halo
through-focus performance
Descripción
Sumario:PURPOSE. To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS. Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standardization eye model. The modulation transfer function (MTF) at the IOLs' foci was obtained with pupils ranging from 2.0 to 5.0 mm. Through-focus MTF curves (at 50 cycles/mm) were compared among all the IOLs. The halo formation and characteristics were obtained from image analysis. RESULTS. The multifocal IOLs studied in this work showed, at their foci, secondary out-of-focus images, which originate halos and whose characteristics depend on the lens design and pupil size. The smallest halo occurred for the distance focus of the SV25T0. The distance and near foci of the SV25T0 yielded, respectively, the best and lowest optical quality among the studied IOLs. The distance focus of the ZKB00, AT LISA, and AT LISA tri were of similar quality, but the near focus of the ZKB00 outperformed the near foci of the rest of the IOLs. The IOLs' optical performance gradually deteriorates as pupil increases. CONCLUSIONS. Differences in the design of the diffractive IOLs translate into differences in optical quality at their foci, through-focus performance, and halo features, which can offer further information to surgeons when selecting which IOL to implant.