Influence of relative abundance of isotopes on depth resolution for depth profiling of metal coatings by laser ablation inductively coupled plasma mass spectrometry

A systematic study on the influence of relative abundance of isotopes of elements in the coating (Ac) and in the substrate (As) on both shape of time-resolved signals and depth resolution (Δz) was performed for depth profile analysis of metal coatings on metal substrates by ultraviolet (266 nm) nano...

Descripción completa

Detalles Bibliográficos
Autores: Fariñas, Juan C., Gómez Coedo, Aurora, Dorado López, María Teresa
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2010
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/221716
Acceso en línea:http://hdl.handle.net/10261/221716
Access Level:acceso abierto
Palabra clave:Metal coatings
Depth profiling
Depth resolution
LA-ICP-MS
Descripción
Sumario:A systematic study on the influence of relative abundance of isotopes of elements in the coating (Ac) and in the substrate (As) on both shape of time-resolved signals and depth resolution (Δz) was performed for depth profile analysis of metal coatings on metal substrates by ultraviolet (266 nm) nanosecond laser ablation inductively coupled plasma quadrupole mass spectrometry. Five coated samples with coating thicknesses of the same order of magnitude (20-30 μm) were tested: nickel coating on aluminium, chromium and copper, and steel coated with copper and zinc. A laser repetition rate of 1 Hz and a laser fluence of 21 J cm-2 were used. Five different depth profile types were established, which showed a clear dependence on Ac/As ratio. In general, depth profiles obtained for ratios above 1-10 could not be used to determine Δz. We found that Δz increased non-linearly with Ac/As ratio. The best depth profile types, leading to highest depth resolution and reproducibility, were attained in all cases by using the isotopes with low/medium Ac values and with the highest As values. In these conditions, an improvement of up to 4 times in Δz values was achieved. The average ablation rates were in the range from 0.55 μm pulse-1 for copper coating on steel to 0.83 μm pulse-1 for zinc coating on steel, and the Δz values were between 2.74 μm for nickel coating on chromium and 5.91 μm for nickel coating on copper, with RSD values about 5-8%. © 2009 Elsevier B.V. All rights reserved.