Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA

The research data generated during the current study cannot be shared due to exclusive intellectual property rights of the new Goldmann “CT” convex tonometer secured by a Spanish patent fled with number P201631280 (granted patent), and a European patent fled with number 3520682 (granted patent). How...

Descripción completa

Detalles Bibliográficos
Autores: Iglesias, María, Kudsieh, Bachar, Laiseca, Andrea, Santos, Cristina, Nadal, Jeroni, Barraquer, Rafael I, Casaroli-Marano, Ricardo
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:20.500.12328/4092
Acceso en línea:http://hdl.handle.net/20.500.12328/4092
https://dx.doi.org/10.1186/s12886-022-02309-x
Access Level:acceso abierto
Palabra clave:Tonometria
Biomecànica corneal
Pressió intraocular
Glaucoma
Miopia
LASIK
PRK
Biomecánica corneal
Presión intraocular
Miopía
Tonometría
Tonometry
Corneal biomechanics
Intraocular pressure
Myopia
617
id ES_48873b45bdf3bd409a3d3175de0e06bc
oai_identifier_str oai:recercat.cat:20.500.12328/4092
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
spellingShingle Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
Iglesias, María
Tonometria
Biomecànica corneal
Pressió intraocular
Glaucoma
Miopia
LASIK
PRK
Biomecánica corneal
Presión intraocular
Glaucoma
Miopía
LASIK
PRK
Tonometría
Tonometry
Corneal biomechanics
Intraocular pressure
Glaucoma
Myopia
LASIK
PRK
617
title_short Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_full Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_fullStr Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_full_unstemmed Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_sort Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
dc.creator.none.fl_str_mv Iglesias, María
Kudsieh, Bachar
Laiseca, Andrea
Santos, Cristina
Nadal, Jeroni
Barraquer, Rafael I
Casaroli-Marano, Ricardo
author Iglesias, María
author_facet Iglesias, María
Kudsieh, Bachar
Laiseca, Andrea
Santos, Cristina
Nadal, Jeroni
Barraquer, Rafael I
Casaroli-Marano, Ricardo
author_role author
author2 Kudsieh, Bachar
Laiseca, Andrea
Santos, Cristina
Nadal, Jeroni
Barraquer, Rafael I
Casaroli-Marano, Ricardo
author2_role author
author
author
author
author
author
dc.subject.none.fl_str_mv Tonometria
Biomecànica corneal
Pressió intraocular
Glaucoma
Miopia
LASIK
PRK
Biomecánica corneal
Presión intraocular
Glaucoma
Miopía
LASIK
PRK
Tonometría
Tonometry
Corneal biomechanics
Intraocular pressure
Glaucoma
Myopia
LASIK
PRK
617
topic Tonometria
Biomecànica corneal
Pressió intraocular
Glaucoma
Miopia
LASIK
PRK
Biomecánica corneal
Presión intraocular
Glaucoma
Miopía
LASIK
PRK
Tonometría
Tonometry
Corneal biomechanics
Intraocular pressure
Glaucoma
Myopia
LASIK
PRK
617
description The research data generated during the current study cannot be shared due to exclusive intellectual property rights of the new Goldmann “CT” convex tonometer secured by a Spanish patent fled with number P201631280 (granted patent), and a European patent fled with number 3520682 (granted patent). However, the data are available from the corresponding author upon reasonable request.
publishDate 2022
dc.date.none.fl_str_mv 2022
dc.type.none.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/20.500.12328/4092
https://dx.doi.org/10.1186/s12886-022-02309-x
url http://hdl.handle.net/20.500.12328/4092
https://dx.doi.org/10.1186/s12886-022-02309-x
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv BMC Ophthalmology
22
dc.rights.none.fl_str_mv https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 9
dc.publisher.none.fl_str_mv Springer Nature
publisher.none.fl_str_mv Springer Nature
dc.source.none.fl_str_mv reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869407365707595776
spelling Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORAIglesias, MaríaKudsieh, BacharLaiseca, AndreaSantos, CristinaNadal, JeroniBarraquer, Rafael ICasaroli-Marano, RicardoTonometriaBiomecànica cornealPressió intraocularGlaucomaMiopiaLASIKPRKBiomecánica cornealPresión intraocularGlaucomaMiopíaLASIKPRKTonometríaTonometryCorneal biomechanicsIntraocular pressureGlaucomaMyopiaLASIKPRK617The research data generated during the current study cannot be shared due to exclusive intellectual property rights of the new Goldmann “CT” convex tonometer secured by a Spanish patent fled with number P201631280 (granted patent), and a European patent fled with number 3520682 (granted patent). However, the data are available from the corresponding author upon reasonable request.Background: The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA). Methods: Prospective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA. Results: Twelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703-0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: - 0.185 - 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = - 0.266, 95% CI: - 3.896 - 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: - 0.332 - 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182). Conclusions: Twelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy.info:eu-repo/semantics/publishedVersionSpringer Nature2022info:eu-repo/semantics/article9http://hdl.handle.net/20.500.12328/4092https://dx.doi.org/10.1186/s12886-022-02309-xreponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésBMC Ophthalmology22This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:20.500.12328/40922026-05-29T05:05:01Z
score 15,81155