Measuring low-current discharges from grounded rods under high background electric fields
This work presents the development of an inductive current sensor for measuring pulsating corona discharges observed under high background electric field. Laboratory and field experiments in different setups are used to corroborate the discharge features. The first location is on the roof of a regul...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2023 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/388722 |
| Acceso en línea: | https://hdl.handle.net/2117/388722 https://dx.doi.org/10.1016/j.epsr.2023.109139 |
| Access Level: | acceso abierto |
| Palabra clave: | Lightning Corona discharge Upward leader Llamps Àrees temàtiques de la UPC::Enginyeria elèctrica |
| id |
ES_3af1a7a19ca28b6bef5628fa02e8c166 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/388722 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Measuring low-current discharges from grounded rods under high background electric fieldsSousa Arcanjo, Marcelo Augusto|||0000-0002-8620-5079Montanya Puig, JoanUrbani, Michele|||0000-0002-9148-2740Lorenzo, VictorLightningCorona dischargeLightningUpward leaderLlampsÀrees temàtiques de la UPC::Enginyeria elèctricaThis work presents the development of an inductive current sensor for measuring pulsating corona discharges observed under high background electric field. Laboratory and field experiments in different setups are used to corroborate the discharge features. The first location is on the roof of a regular building, and the second is on a flat area. Due to the enhancement of the E-field caused by lightning strikes in the vicinity of a grounded rod with a sharp tip, positive and negative pulses before or after the strikes are observed. When lightning activity is far from the structure, but the electric field remains high, pulses are also observed. Finally, one prototype of this sensor was modified to work as a pulse detector with a higher current threshold, allowing detections of leader currents above 0.5 A. The sensor performance is validated in the laboratory and investigated in the field, in association with lightning events.Peer ReviewedElsevier20232023-04-0120232023-06-15journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/388722https://dx.doi.org/10.1016/j.epsr.2023.109139reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/3887222026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Measuring low-current discharges from grounded rods under high background electric fields |
| title |
Measuring low-current discharges from grounded rods under high background electric fields |
| spellingShingle |
Measuring low-current discharges from grounded rods under high background electric fields Sousa Arcanjo, Marcelo Augusto|||0000-0002-8620-5079 Lightning Corona discharge Lightning Upward leader Llamps Àrees temàtiques de la UPC::Enginyeria elèctrica |
| title_short |
Measuring low-current discharges from grounded rods under high background electric fields |
| title_full |
Measuring low-current discharges from grounded rods under high background electric fields |
| title_fullStr |
Measuring low-current discharges from grounded rods under high background electric fields |
| title_full_unstemmed |
Measuring low-current discharges from grounded rods under high background electric fields |
| title_sort |
Measuring low-current discharges from grounded rods under high background electric fields |
| dc.creator.none.fl_str_mv |
Sousa Arcanjo, Marcelo Augusto|||0000-0002-8620-5079 Montanya Puig, Joan Urbani, Michele|||0000-0002-9148-2740 Lorenzo, Victor |
| author |
Sousa Arcanjo, Marcelo Augusto|||0000-0002-8620-5079 |
| author_facet |
Sousa Arcanjo, Marcelo Augusto|||0000-0002-8620-5079 Montanya Puig, Joan Urbani, Michele|||0000-0002-9148-2740 Lorenzo, Victor |
| author_role |
author |
| author2 |
Montanya Puig, Joan Urbani, Michele|||0000-0002-9148-2740 Lorenzo, Victor |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Lightning Corona discharge Lightning Upward leader Llamps Àrees temàtiques de la UPC::Enginyeria elèctrica |
| topic |
Lightning Corona discharge Lightning Upward leader Llamps Àrees temàtiques de la UPC::Enginyeria elèctrica |
| description |
This work presents the development of an inductive current sensor for measuring pulsating corona discharges observed under high background electric field. Laboratory and field experiments in different setups are used to corroborate the discharge features. The first location is on the roof of a regular building, and the second is on a flat area. Due to the enhancement of the E-field caused by lightning strikes in the vicinity of a grounded rod with a sharp tip, positive and negative pulses before or after the strikes are observed. When lightning activity is far from the structure, but the electric field remains high, pulses are also observed. Finally, one prototype of this sensor was modified to work as a pulse detector with a higher current threshold, allowing detections of leader currents above 0.5 A. The sensor performance is validated in the laboratory and investigated in the field, in association with lightning events. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2023 2023-04-01 2023 2023-06-15 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/388722 https://dx.doi.org/10.1016/j.epsr.2023.109139 |
| url |
https://hdl.handle.net/2117/388722 https://dx.doi.org/10.1016/j.epsr.2023.109139 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869406274433581056 |
| score |
15,300724 |