Optical and structural properties of SiOxNyHz films deposited by electron cyclotron resonance and their correlation with composition

SiOxNyHz films were deposited from O-2, N-2, and SiH4 gas mixtures at room temperature using the electron cyclotron resonance plasma method. The absolute concentrations of all the species present in the films (Si, O, N, and H) were measured with high precision by heavy-ion elastic recoil detection a...

Descripción completa

Detalles Bibliográficos
Autores: Martil De La Plaza, Ignacio, González Díaz, Germán, Prado Millán, Álvaro Del, San Andrés Serrano, Enrique
Tipo de recurso: artículo
Fecha de publicación:2003
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/51134
Acceso en línea:https://hdl.handle.net/20.500.14352/51134
Access Level:acceso abierto
Palabra clave:537
Silicon-Oxynitride Films
Chemical-Vapor-Deposition
Paramagnetic Point-Defects
Nitride Thin-Films
A-SiNx-H
Substrate-Temperature
Tetrahedron Model
Plasma
Nitrogen
Growth.
Electricidad
Electrónica (Física)
2202.03 Electricidad
Descripción
Sumario:SiOxNyHz films were deposited from O-2, N-2, and SiH4 gas mixtures at room temperature using the electron cyclotron resonance plasma method. The absolute concentrations of all the species present in the films (Si, O, N, and H) were measured with high precision by heavy-ion elastic recoil detection analysis. The composition of the films was controlled over the whole composition range by adjusting the precursor-gases flow ratio during deposition. The relative incorporation of O and N is determined by the ratio Q = phi(O-2)/(phi(SiH4) and the relative content of Si is determined by R =[phi(O-2)+phi(N-2)]/phi(SiH4) where phi(SiH4), phi(O-2), and phi(N-2) are the SiH4, O-2, and N-2 gas flows, respectively. The optical properties (infrared absorption and refractive index) and the density of paramagnetic defects were analyzed in dependence on the film composition. Single-phase homogeneous films were obtained at low SiH4 partial pressure during deposition; while those samples deposited at high SiH4 partial pressure show evidence of separation of two phases. The refractive index was controlled over the whole range between silicon nitride and silicon oxide, with values slightly lower than in stoichiometric films due to the incorporation of H, which results in a lower density of the films. The most important paramagnetic defects detected in the films were the K center and the E' center. Defects related to N were also detected in some samples. The total density of defects in SiOxNyHz films was higher than in SiO2 and lower than in silicon nitride films.