Visual outcomes after progressive apodized diffractive intraocular lens implantation

Purpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (M...

Descripción completa

Detalles Bibliográficos
Autores: García-Bella, Javier, Ventura-Abreu, Néstor, Morales-Fernández, Laura, Talavero-González, Paula, Carballo Álvarez, Jesús, Sanz Fernández, Juan Carlos, Vázquez Molini, José María, Martínez De La Casa Fernández-Borrella, José María
Tipo de recurso: artículo
Fecha de publicación:2018
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/114871
Acceso en línea:https://hdl.handle.net/20.500.14352/114871
Access Level:acceso abierto
Palabra clave:617.7-089.243
681.73
Intraocular lens
Progressived apodized
Cataract
Visual function
Oftalmología
Óptica oftálmica
Cirugía
Óptica y optometría
3201.09 Oftalmología
2209.15 Optometría
3213.09 Cirugía Ocular
3311.09 Lentes
id ES_2fbc22701c6ea7df99b3c84af3d8b917
oai_identifier_str oai:docta.ucm.es:20.500.14352/114871
network_acronym_str ES
network_name_str España
repository_id_str
spelling Visual outcomes after progressive apodized diffractive intraocular lens implantationGarcía-Bella, JavierVentura-Abreu, NéstorMorales-Fernández, LauraTalavero-González, PaulaCarballo Álvarez, JesúsSanz Fernández, Juan CarlosVázquez Molini, José MaríaMartínez De La Casa Fernández-Borrella, José María617.7-089.243681.73Intraocular lensProgressived apodizedCataractVisual functionOftalmologíaÓptica oftálmicaCirugíaÓptica y optometría3201.09 Oftalmología2209.15 Optometría3213.09 Cirugía Ocular3311.09 LentesPurpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (Medicontur, Hungary) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were determined. Intermediate at 65 cm (DCIVA) and near at 40 cm (DCNVA) visual acuity were also measured, both with best distance correction. The CSV-1000 test chart was used to assess contrast sensitivity (CS). Defocus curves were constructed under photopic and mesopic conditions, determining binocular best-corrected visual acuity over the range +1.50 D to -4.00 D in 0.50-D steps. A KR-1W Wavefront Analyzer was used to measure pupil size and aberrometric outcomes. Presence and type of dysphotopsia were evaluated with the Likert scale. Results: Mesopic mean pupil diameter was 4.58 ± 0.73 mm. The mean values at 3 months were UDVA 0.03 ± 0.09, CDVA -0.05 ± 0.06, DCIVA 0.20 ± 0.07, and DCNVA 0.11 ± 0.08. Mean CS for the 4 frequencies examined were 1.66 ± 0.16, 1.75 ± 0.14, 1.39 ± 0.22, and 0.96 ± 0.19. Significant differences were observed in defocus curves for photopic and mesopic conditions. A significant correlation between pupil diameter and the dysphotopic photopic was found (r = 0.62; p = 0.02). Conclusions: The evaluated progressive apodized diffractive design IOL provides effective restoration of visual function in far and near vision distance with an adequate intermediate visual quality between -1.00 and -1.50 focus.Sage PublicationsUniversidad Complutense de Madrid20182018-05-0120182018-05-01journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/114871reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/1148712026-06-02T12:44:21Z
dc.title.none.fl_str_mv Visual outcomes after progressive apodized diffractive intraocular lens implantation
title Visual outcomes after progressive apodized diffractive intraocular lens implantation
spellingShingle Visual outcomes after progressive apodized diffractive intraocular lens implantation
García-Bella, Javier
617.7-089.243
681.73
Intraocular lens
Progressived apodized
Cataract
Visual function
Oftalmología
Óptica oftálmica
Cirugía
Óptica y optometría
3201.09 Oftalmología
2209.15 Optometría
3213.09 Cirugía Ocular
3311.09 Lentes
title_short Visual outcomes after progressive apodized diffractive intraocular lens implantation
title_full Visual outcomes after progressive apodized diffractive intraocular lens implantation
title_fullStr Visual outcomes after progressive apodized diffractive intraocular lens implantation
title_full_unstemmed Visual outcomes after progressive apodized diffractive intraocular lens implantation
title_sort Visual outcomes after progressive apodized diffractive intraocular lens implantation
dc.creator.none.fl_str_mv García-Bella, Javier
Ventura-Abreu, Néstor
Morales-Fernández, Laura
Talavero-González, Paula
Carballo Álvarez, Jesús
Sanz Fernández, Juan Carlos
Vázquez Molini, José María
Martínez De La Casa Fernández-Borrella, José María
author García-Bella, Javier
author_facet García-Bella, Javier
Ventura-Abreu, Néstor
Morales-Fernández, Laura
Talavero-González, Paula
Carballo Álvarez, Jesús
Sanz Fernández, Juan Carlos
Vázquez Molini, José María
Martínez De La Casa Fernández-Borrella, José María
author_role author
author2 Ventura-Abreu, Néstor
Morales-Fernández, Laura
Talavero-González, Paula
Carballo Álvarez, Jesús
Sanz Fernández, Juan Carlos
Vázquez Molini, José María
Martínez De La Casa Fernández-Borrella, José María
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidad Complutense de Madrid
dc.subject.none.fl_str_mv 617.7-089.243
681.73
Intraocular lens
Progressived apodized
Cataract
Visual function
Oftalmología
Óptica oftálmica
Cirugía
Óptica y optometría
3201.09 Oftalmología
2209.15 Optometría
3213.09 Cirugía Ocular
3311.09 Lentes
topic 617.7-089.243
681.73
Intraocular lens
Progressived apodized
Cataract
Visual function
Oftalmología
Óptica oftálmica
Cirugía
Óptica y optometría
3201.09 Oftalmología
2209.15 Optometría
3213.09 Cirugía Ocular
3311.09 Lentes
description Purpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (Medicontur, Hungary) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were determined. Intermediate at 65 cm (DCIVA) and near at 40 cm (DCNVA) visual acuity were also measured, both with best distance correction. The CSV-1000 test chart was used to assess contrast sensitivity (CS). Defocus curves were constructed under photopic and mesopic conditions, determining binocular best-corrected visual acuity over the range +1.50 D to -4.00 D in 0.50-D steps. A KR-1W Wavefront Analyzer was used to measure pupil size and aberrometric outcomes. Presence and type of dysphotopsia were evaluated with the Likert scale. Results: Mesopic mean pupil diameter was 4.58 ± 0.73 mm. The mean values at 3 months were UDVA 0.03 ± 0.09, CDVA -0.05 ± 0.06, DCIVA 0.20 ± 0.07, and DCNVA 0.11 ± 0.08. Mean CS for the 4 frequencies examined were 1.66 ± 0.16, 1.75 ± 0.14, 1.39 ± 0.22, and 0.96 ± 0.19. Significant differences were observed in defocus curves for photopic and mesopic conditions. A significant correlation between pupil diameter and the dysphotopic photopic was found (r = 0.62; p = 0.02). Conclusions: The evaluated progressive apodized diffractive design IOL provides effective restoration of visual function in far and near vision distance with an adequate intermediate visual quality between -1.00 and -1.50 focus.
publishDate 2018
dc.date.none.fl_str_mv 2018
2018-05-01
2018
2018-05-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
AM
http://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.14352/114871
url https://hdl.handle.net/20.500.14352/114871
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sage Publications
publisher.none.fl_str_mv Sage Publications
dc.source.none.fl_str_mv reponame:Docta Complutense
instname:Universidad Complutense de Madrid (UCM)
instname_str Universidad Complutense de Madrid (UCM)
reponame_str Docta Complutense
collection Docta Complutense
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869405497763823616
score 15.81155