Visual outcomes after progressive apodized diffractive intraocular lens implantation

Purpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (M...

Descripción completa

Detalles Bibliográficos
Autores: García-Bella, Javier, Ventura-Abreu, Néstor, Morales-Fernández, Laura, Talavero-González, Paula, Carballo Álvarez, Jesús, Sanz Fernández, Juan Carlos, Vázquez Molini, José María, Martínez De La Casa Fernández-Borrella, José María
Tipo de recurso: artículo
Fecha de publicación:2018
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/114871
Acceso en línea:https://hdl.handle.net/20.500.14352/114871
Access Level:acceso abierto
Palabra clave:617.7-089.243
681.73
Intraocular lens
Progressived apodized
Cataract
Visual function
Oftalmología
Óptica oftálmica
Cirugía
Óptica y optometría
3201.09 Oftalmología
2209.15 Optometría
3213.09 Cirugía Ocular
3311.09 Lentes
Descripción
Sumario:Purpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (Medicontur, Hungary) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were determined. Intermediate at 65 cm (DCIVA) and near at 40 cm (DCNVA) visual acuity were also measured, both with best distance correction. The CSV-1000 test chart was used to assess contrast sensitivity (CS). Defocus curves were constructed under photopic and mesopic conditions, determining binocular best-corrected visual acuity over the range +1.50 D to -4.00 D in 0.50-D steps. A KR-1W Wavefront Analyzer was used to measure pupil size and aberrometric outcomes. Presence and type of dysphotopsia were evaluated with the Likert scale. Results: Mesopic mean pupil diameter was 4.58 ± 0.73 mm. The mean values at 3 months were UDVA 0.03 ± 0.09, CDVA -0.05 ± 0.06, DCIVA 0.20 ± 0.07, and DCNVA 0.11 ± 0.08. Mean CS for the 4 frequencies examined were 1.66 ± 0.16, 1.75 ± 0.14, 1.39 ± 0.22, and 0.96 ± 0.19. Significant differences were observed in defocus curves for photopic and mesopic conditions. A significant correlation between pupil diameter and the dysphotopic photopic was found (r = 0.62; p = 0.02). Conclusions: The evaluated progressive apodized diffractive design IOL provides effective restoration of visual function in far and near vision distance with an adequate intermediate visual quality between -1.00 and -1.50 focus.