Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm

Objective: Maximum diameter (MD) is the established rupture predictor for abdominal aortic aneurysm (AAA). However, biomechanical markers from finite element analysis (FEA) could be more accurate predictors for these patients. In this study, the association between peak wall stress (PWS) and MD with...

Descripción completa

Detalles Bibliográficos
Autores: Soto, B, Vila, L, Dilme, JF, Escudero, JR, Bellmunt, S, Camacho, M
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2017
País:España
Institución:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
Repositorio:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
OAI Identifier:oai:iibsantpau.fundanetsuite.com:p5960
Acceso en línea:https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=5960
Access Level:acceso abierto
Palabra clave:Abdominal aortic aneurysm
Morphological variables
Biomechanical variables
Finite element analysis
Symptomatic aneurysm
id ES_27bbf3d5f80754655b734dd2eea69fb7
oai_identifier_str oai:iibsantpau.fundanetsuite.com:p5960
network_acronym_str ES
network_name_str España
repository_id_str
spelling Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic AneurysmSoto, BVila, LDilme, JFEscudero, JRBellmunt, SCamacho, MAbdominal aortic aneurysmMorphological variablesBiomechanical variablesFinite element analysisSymptomatic aneurysmObjective: Maximum diameter (MD) is the established rupture predictor for abdominal aortic aneurysm (AAA). However, biomechanical markers from finite element analysis (FEA) could be more accurate predictors for these patients. In this study, the association between peak wall stress (PWS) and MD with symptoms of AAA was evaluated. Methods: Patients diagnosed with infrarenal non-ruptured AAA at the centre between 2009 and 2015 were included. Clinical data, morphological variables (including MD), and the biomechanical variables PWS and diameter normalised PWS (dnPWS) in symptomatic (sAAA) and asymptomatic AAA patients (aAAA) were included. Results: A total of 170 patients were analysed, 153 aAAA and 17 sAAA. MD was significantly greater in sAAA patients than in aAAA patients (70.4 mm, 95% CI 66.4-86.0 vs. 59.1 mm, 95% CI 53.7-67.8, respectively; p = .002). PWS was also significantly higher in the sAAA group (324.6 kPa, 95% CI 217.4-399.5 vs. 199.2 kPa, 95% CI 165.6-239.5; p < .01). No differences in MD were found in patients with an AAA >= 65 mm (43 aAAA and 14 sAAA); however, both PWS (327.4 kPa, 95% CI 239.0-473.3 vs. 229.4 kPa, 95% CI 210.0 to 289.4; p = .020) and dnPWS (4.3, 95% CI 3.17-4.67 vs. 3.03, 95% CI 2.8-3.49; p = .004) were higher in sAAA than in aAAA. Conclusions: This study suggests that MD and the biomechanical parameters obtained by finite element analysis are greater in sAAA than in aAAA. However, considering patients with MD >= 65 mm alone, only PWS, and particularly dnPWS, were able to differentiate sAAA from aAAA. (C) 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.W B SAUNDERS CO LTD2017info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=5960EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERYISSN: 10785884ISSNe: 15322165reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pauinstname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)Inglésinfo:eu-repo/semantics/openAccessoai:iibsantpau.fundanetsuite.com:p59602026-06-14T12:41:47Z
dc.title.none.fl_str_mv Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
title Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
spellingShingle Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
Soto, B
Abdominal aortic aneurysm
Morphological variables
Biomechanical variables
Finite element analysis
Symptomatic aneurysm
title_short Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
title_full Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
title_fullStr Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
title_full_unstemmed Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
title_sort Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm
dc.creator.none.fl_str_mv Soto, B
Vila, L
Dilme, JF
Escudero, JR
Bellmunt, S
Camacho, M
author Soto, B
author_facet Soto, B
Vila, L
Dilme, JF
Escudero, JR
Bellmunt, S
Camacho, M
author_role author
author2 Vila, L
Dilme, JF
Escudero, JR
Bellmunt, S
Camacho, M
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv Abdominal aortic aneurysm
Morphological variables
Biomechanical variables
Finite element analysis
Symptomatic aneurysm
topic Abdominal aortic aneurysm
Morphological variables
Biomechanical variables
Finite element analysis
Symptomatic aneurysm
description Objective: Maximum diameter (MD) is the established rupture predictor for abdominal aortic aneurysm (AAA). However, biomechanical markers from finite element analysis (FEA) could be more accurate predictors for these patients. In this study, the association between peak wall stress (PWS) and MD with symptoms of AAA was evaluated. Methods: Patients diagnosed with infrarenal non-ruptured AAA at the centre between 2009 and 2015 were included. Clinical data, morphological variables (including MD), and the biomechanical variables PWS and diameter normalised PWS (dnPWS) in symptomatic (sAAA) and asymptomatic AAA patients (aAAA) were included. Results: A total of 170 patients were analysed, 153 aAAA and 17 sAAA. MD was significantly greater in sAAA patients than in aAAA patients (70.4 mm, 95% CI 66.4-86.0 vs. 59.1 mm, 95% CI 53.7-67.8, respectively; p = .002). PWS was also significantly higher in the sAAA group (324.6 kPa, 95% CI 217.4-399.5 vs. 199.2 kPa, 95% CI 165.6-239.5; p < .01). No differences in MD were found in patients with an AAA >= 65 mm (43 aAAA and 14 sAAA); however, both PWS (327.4 kPa, 95% CI 239.0-473.3 vs. 229.4 kPa, 95% CI 210.0 to 289.4; p = .020) and dnPWS (4.3, 95% CI 3.17-4.67 vs. 3.03, 95% CI 2.8-3.49; p = .004) were higher in sAAA than in aAAA. Conclusions: This study suggests that MD and the biomechanical parameters obtained by finite element analysis are greater in sAAA than in aAAA. However, considering patients with MD >= 65 mm alone, only PWS, and particularly dnPWS, were able to differentiate sAAA from aAAA. (C) 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
publishDate 2017
dc.date.none.fl_str_mv 2017
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=5960
url https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=5960
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv W B SAUNDERS CO LTD
publisher.none.fl_str_mv W B SAUNDERS CO LTD
dc.source.none.fl_str_mv EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY
ISSN: 10785884
ISSNe: 15322165
reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
instname_str Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)