Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values
This dataset contains experimental measurements of corona inception voltage (CIV) and breakdown voltage for air at various pressures and electrode gap distances, obtained under alternating current (AC), positive direct current (DC+), and negative direct current (DC–) excitation. All experiments were...
| Autores: | , |
|---|---|
| Formato: | conjunto de datos |
| Fecha de publicación: | 2025 |
| País: | España |
| Recursos: | Consorci de Serveis Universitaris de Catalunya (CSUC) |
| Repositorio: | CORA.Repositori de Dades de Recerca |
| OAI Identifier: | oai:dnet:cora.rdr____::1958f23c99ec45c9c829119326578aeb |
| Acesso em linha: | https://doi.org/10.34810/DATA2646 |
| Access Level: | acceso abierto |
| Palavra-chave: | Engineering Physics Corona discharges Breakdown Paschen curve |
| id |
ES_262a889fa62d3fb3fe6f2e7ce1d32da2 |
|---|---|
| oai_identifier_str |
oai:dnet:cora.rdr____::1958f23c99ec45c9c829119326578aeb |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d valuesRiba Ruiz, Jordi-RogerSoltany, MiladEngineeringPhysicsCorona dischargesBreakdownPaschen curveThis dataset contains experimental measurements of corona inception voltage (CIV) and breakdown voltage for air at various pressures and electrode gap distances, obtained under alternating current (AC), positive direct current (DC+), and negative direct current (DC–) excitation. All experiments were conducted in a controlled high-voltage laboratory using a rod-to-plane electrode configuration and a low-pressure chamber. The results are compared with the Paschen curve for air as reported by Dakin et al. (1974). This dataset supports studies of gas discharge behavior, corona inception mechanisms, and complete breakdown characteristics under different voltage polarities and pressures.CORA.Repositori de Dades de RecercaRiba Ruiz, Jordi Roger170(MP)2025info:eu-repo/semantics/datasethttps://doi.org/10.34810/DATA2646reponame:CORA.Repositori de Dades de Recercainstname:Consorci de Serveis Universitaris de Catalunya (CSUC)Inglésinfo:eu-repo/semantics/openAccessCC BY 4.0oai:dnet:cora.rdr____::1958f23c99ec45c9c829119326578aeb2026-06-17T12:20:17Z |
| dc.title.none.fl_str_mv |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| title |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| spellingShingle |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values Riba Ruiz, Jordi-Roger Engineering Physics Corona discharges Breakdown Paschen curve |
| title_short |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| title_full |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| title_fullStr |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| title_full_unstemmed |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| title_sort |
Corona inception and complete breakdown voltages in air under AC, positive DC, and negative DC supply at different p·d values |
| dc.creator.none.fl_str_mv |
Riba Ruiz, Jordi-Roger Soltany, Milad |
| author |
Riba Ruiz, Jordi-Roger |
| author_facet |
Riba Ruiz, Jordi-Roger Soltany, Milad |
| author_role |
author |
| author2 |
Soltany, Milad |
| author2_role |
author |
| dc.contributor.none.fl_str_mv |
Riba Ruiz, Jordi Roger 170(MP) |
| dc.subject.none.fl_str_mv |
Engineering Physics Corona discharges Breakdown Paschen curve |
| topic |
Engineering Physics Corona discharges Breakdown Paschen curve |
| description |
This dataset contains experimental measurements of corona inception voltage (CIV) and breakdown voltage for air at various pressures and electrode gap distances, obtained under alternating current (AC), positive direct current (DC+), and negative direct current (DC–) excitation. All experiments were conducted in a controlled high-voltage laboratory using a rod-to-plane electrode configuration and a low-pressure chamber. The results are compared with the Paschen curve for air as reported by Dakin et al. (1974). This dataset supports studies of gas discharge behavior, corona inception mechanisms, and complete breakdown characteristics under different voltage polarities and pressures. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2025 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/dataset |
| format |
dataset |
| dc.identifier.none.fl_str_mv |
https://doi.org/10.34810/DATA2646 |
| url |
https://doi.org/10.34810/DATA2646 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess CC BY 4.0 |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
CC BY 4.0 |
| dc.publisher.none.fl_str_mv |
CORA.Repositori de Dades de Recerca |
| publisher.none.fl_str_mv |
CORA.Repositori de Dades de Recerca |
| dc.source.none.fl_str_mv |
reponame:CORA.Repositori de Dades de Recerca instname:Consorci de Serveis Universitaris de Catalunya (CSUC) |
| instname_str |
Consorci de Serveis Universitaris de Catalunya (CSUC) |
| reponame_str |
CORA.Repositori de Dades de Recerca |
| collection |
CORA.Repositori de Dades de Recerca |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869404805929107456 |
| score |
15,811543 |