Smartphone Photogrammetric Assessment for Head Measurements
[EN] The assessment of cranial deformation is relevant in the field of medicine dealing with infants, especially in paediatric neurosurgery and paediatrics. To address this demand, the smartphone-based solution PhotoMeDAS has been developed, harnessing mobile devices to create three-dimensional (3D)...
| Autores: | , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2023 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/205064 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/205064 |
| Access Level: | acceso abierto |
| Palabra clave: | 3D measurement Metric assessment Cranial deformation Smartphone device 3D scanning INGENIERIA CARTOGRAFICA, GEODESIA Y FOTOGRAMETRIA 03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edades 04.- Garantizar una educación de calidad inclusiva y equitativa, y promover las oportunidades de aprendizaje permanente para todos 09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación |
| Sumario: | [EN] The assessment of cranial deformation is relevant in the field of medicine dealing with infants, especially in paediatric neurosurgery and paediatrics. To address this demand, the smartphone-based solution PhotoMeDAS has been developed, harnessing mobile devices to create three-dimensional (3D) models of infants¿ heads and, from them, automatic cranial deformation reports. Therefore, it is crucial to examine the accuracy achievable with different mobile devices under similar conditions so prospective users can consider this aspect when using the smartphone-based solution. This study compares the linear accuracy obtained from three smartphone models (Samsung Galaxy S22 Ultra, S22, and S22+). Twelve measurements are taken with each mobile device using a coded cap on a head mannequin. For processing, three different bundle adjustment implementations are tested with and without self-calibration. After photogrammetric processing, the 3D coordinates are obtained. A comparison is made among spatially distributed distances across the head with PhotoMeDAS vs. ground truth established with a Creaform ACADEMIA 50 while-light 3D scanner. With a homogeneous scale factor for all the smartphones, the results showed that the average accuracy for the S22 smartphone is ¿1.15 0.53 mm, for the S22+, 0.95 0.40 mm, and for the S22 Ultra, ¿1.8 0.45 mm. Worth noticing is that a substantial improvement is achieved regardless of whether the scale factor is introduced per device. |
|---|