Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility
[EN] After the injection of borated water during accidental sequences, the intrusion of nitrogen gas from the accumulators once emptied can degrade heat transfer mechanisms and thus hinder core cooling. The non-condensable gas that enters the cold legs transfers and accumulates in the U-tubes of the...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2025 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/226861 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/226861 |
| Access Level: | acceso abierto |
| Palabra clave: | Nitrogen intrusion TRACE5 Large scale test facility SBLOCA |
| id |
ES_0929db7f024eb9f22759cd98eead3a73 |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/226861 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facilityTen-Gallardo, TomásGallardo Bermell, Sergio|||0000-0002-3703-9983M. Lorduy|||0000-0002-8942-8278Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080XNitrogen intrusionTRACE5Large scale test facilitySBLOCA[EN] After the injection of borated water during accidental sequences, the intrusion of nitrogen gas from the accumulators once emptied can degrade heat transfer mechanisms and thus hinder core cooling. The non-condensable gas that enters the cold legs transfers and accumulates in the U-tubes of the steam generators and their outlet plenums. This can cause flow stagnation and even prevent reflux cooling. Furthermore, a temporary and fluctuating increase in primary pressure may occur, disabling the low-pressure injection system pumps to restore the inventory. In this scenario, it is essential to confirm the effectiveness of the accident management measures under the influence of non-condensable gas. To date, several experimental studies have been conducted within the framework of OECD/NEA programs at experimental facilities such as LSTF, PKL, or ATLAS (all related to PWRtype designs) where the issue of non-condensable gas intrusion has been studied, but always as a secondary objective of the analyzed sequences. In this work, three SBLOCA in the reactor pressure vessel of the LSTF facility are analyzed to determine the effect of nitrogen intrusion in the primary system. For calculations, the thermalhydraulic code TRACE5 patch 5 is used. Results include the evolution of the main thermal-hydraulic parameters (pressures, mass flow rates and temperatures) and sensitivity cases for different scenarios of nitrogen intrusion. Based on the analysis of three experiments, it can be concluded that while nitrogen accumulation in the U-tubes is a common effect, the activation of safety systems such as LPIS depends on the location, size of the break and action management measures.This work has been developed under the project "Analisis del impacto de la intrusion de gas nitrogeno en el circuito primario de refrigeracion de plantas nucleares" (SUBV-6/2023, Subvenciones destinadas a la realizacion de proyectos de I + D + i relacionados con las funciones del CSN) . The authors are grateful to the Spanish Safety Council (CSN) that has financed this project.ElsevierDepartamento de Ingeniería Química y NuclearDepartamento de Estadística e Investigación Operativa Aplicadas y CalidadEscuela Técnica Superior de Ingeniería IndustrialInstituto Universitario de Seguridad Industrial, Radiofísica y MedioambientalConsejo de Seguridad NuclearRepositorio Institucional de la Universitat Politècnica de València Riunet20252025-11-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/226861reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento - No comercial (by-nc) http://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/2268612026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| title |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| spellingShingle |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility Ten-Gallardo, Tomás Nitrogen intrusion TRACE5 Large scale test facility SBLOCA |
| title_short |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| title_full |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| title_fullStr |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| title_full_unstemmed |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| title_sort |
Analysis of nitrogen intrusion from ECCS accumulators in SBLOCA scenarios at LSTF test facility |
| dc.creator.none.fl_str_mv |
Ten-Gallardo, Tomás Gallardo Bermell, Sergio|||0000-0002-3703-9983 M. Lorduy|||0000-0002-8942-8278 Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X |
| author |
Ten-Gallardo, Tomás |
| author_facet |
Ten-Gallardo, Tomás Gallardo Bermell, Sergio|||0000-0002-3703-9983 M. Lorduy|||0000-0002-8942-8278 Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X |
| author_role |
author |
| author2 |
Gallardo Bermell, Sergio|||0000-0002-3703-9983 M. Lorduy|||0000-0002-8942-8278 Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Ingeniería Química y Nuclear Departamento de Estadística e Investigación Operativa Aplicadas y Calidad Escuela Técnica Superior de Ingeniería Industrial Instituto Universitario de Seguridad Industrial, Radiofísica y Medioambiental Consejo de Seguridad Nuclear Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Nitrogen intrusion TRACE5 Large scale test facility SBLOCA |
| topic |
Nitrogen intrusion TRACE5 Large scale test facility SBLOCA |
| description |
[EN] After the injection of borated water during accidental sequences, the intrusion of nitrogen gas from the accumulators once emptied can degrade heat transfer mechanisms and thus hinder core cooling. The non-condensable gas that enters the cold legs transfers and accumulates in the U-tubes of the steam generators and their outlet plenums. This can cause flow stagnation and even prevent reflux cooling. Furthermore, a temporary and fluctuating increase in primary pressure may occur, disabling the low-pressure injection system pumps to restore the inventory. In this scenario, it is essential to confirm the effectiveness of the accident management measures under the influence of non-condensable gas. To date, several experimental studies have been conducted within the framework of OECD/NEA programs at experimental facilities such as LSTF, PKL, or ATLAS (all related to PWRtype designs) where the issue of non-condensable gas intrusion has been studied, but always as a secondary objective of the analyzed sequences. In this work, three SBLOCA in the reactor pressure vessel of the LSTF facility are analyzed to determine the effect of nitrogen intrusion in the primary system. For calculations, the thermalhydraulic code TRACE5 patch 5 is used. Results include the evolution of the main thermal-hydraulic parameters (pressures, mass flow rates and temperatures) and sensitivity cases for different scenarios of nitrogen intrusion. Based on the analysis of three experiments, it can be concluded that while nitrogen accumulation in the U-tubes is a common effect, the activation of safety systems such as LPIS depends on the location, size of the break and action management measures. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2025 2025-11-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/226861 |
| url |
https://riunet.upv.es/handle/10251/226861 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento - No comercial (by-nc) http://creativecommons.org/licenses/by-nc/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento - No comercial (by-nc) http://creativecommons.org/licenses/by-nc/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869403090124275712 |
| score |
15,812429 |