Optical grating coupler biosensor and biomedical applications

Biosensors are nowadays a powerful tool to enable the detection of specific biological interactions and to evaluate the concentration dependence in the response. A biosensor usually consists of three different parts: the sample to be measured, the transducer and the electronic system that amplifies...

Descripción completa

Detalles Bibliográficos
Autor: Diéguez Moure, Lorena
Tipo de recurso: tesis doctoral
Estado:Versión publicada
Fecha de publicación:2012
País:España
Institución:CBUC, CESCA
Repositorio:TDR. Tesis Doctorales en Red
OAI Identifier:oai:www.tdx.cat:10803/101149
Acceso en línea:http://hdl.handle.net/10803/101149
Access Level:acceso abierto
Palabra clave:Electrònica
Electrónica
Electronics
Nanotecnologia
Nanotecnología
Nanotechnology
Detectors òptics
Sensores ópticos
Optical detectors
Ciències Experimentals i Matemàtiques
53
id ES_077fed59d97a1d65cb8d1e346fe0e9a2
oai_identifier_str oai:www.tdx.cat:10803/101149
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv Optical grating coupler biosensor and biomedical applications
title Optical grating coupler biosensor and biomedical applications
spellingShingle Optical grating coupler biosensor and biomedical applications
Diéguez Moure, Lorena
Electrònica
Electrónica
Electronics
Nanotecnologia
Nanotecnología
Nanotechnology
Detectors òptics
Sensores ópticos
Optical detectors
Ciències Experimentals i Matemàtiques
53
title_short Optical grating coupler biosensor and biomedical applications
title_full Optical grating coupler biosensor and biomedical applications
title_fullStr Optical grating coupler biosensor and biomedical applications
title_full_unstemmed Optical grating coupler biosensor and biomedical applications
title_sort Optical grating coupler biosensor and biomedical applications
dc.creator.none.fl_str_mv Diéguez Moure, Lorena
author Diéguez Moure, Lorena
author_facet Diéguez Moure, Lorena
author_role author
dc.contributor.none.fl_str_mv Moreno Sereno, Mauricio
Martínez Fraiz, Elena
Universitat de Barcelona. Departament d'Electrònica
dc.subject.none.fl_str_mv Electrònica
Electrónica
Electronics
Nanotecnologia
Nanotecnología
Nanotechnology
Detectors òptics
Sensores ópticos
Optical detectors
Ciències Experimentals i Matemàtiques
53
topic Electrònica
Electrónica
Electronics
Nanotecnologia
Nanotecnología
Nanotechnology
Detectors òptics
Sensores ópticos
Optical detectors
Ciències Experimentals i Matemàtiques
53
description Biosensors are nowadays a powerful tool to enable the detection of specific biological interactions and to evaluate the concentration dependence in the response. A biosensor usually consists of three different parts: the sample to be measured, the transducer and the electronic system that amplifies the signal, analyzes the data and brings a result to the final user. The transducer includes the bioreceptor (which specifically interacts with the sample) and the interface that transforms the recognition from the bioreceptor into a measurable signal. When the analyte interacts with the bioreceptor, the transducer sends a signal that is processed by the electronics. All this process occurs in an efficient, quick, cheap, easy, simple and specific way. Regarding the type of the transductor, the biosensors can be electrochemical, optical, acoustic, magnetic or thermometric; but overall the most powerful ones are the optical biosensors, and among them the grating coupler. As a technique for investigating processes at the solid/liquid interface, presents high mechanical stability, immunity to electromagnetic interferences and pushes the sensitivity to levels even higher than other techniques and allows for the direct monitoring of macromolecular adsorption. Taking advantage of the last advances in nanotechnology, the goal of this thesis is to study the versatility of an Optical Grating Coupler Biosensor. The design of new grating sensor chips will be investigated, a new calibration technique for the sensors will be proposed and, taking advantage of the technique, different biomedical scenarios will be tested.
publishDate 2012
dc.date.none.fl_str_mv 2012
2013
2013
dc.type.none.fl_str_mv info:eu-repo/semantics/doctoralThesis
info:eu-repo/semantics/publishedVersion
format doctoralThesis
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10803/101149
url http://hdl.handle.net/10803/101149
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 261 p.
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universitat de Barcelona
publisher.none.fl_str_mv Universitat de Barcelona
dc.source.none.fl_str_mv TDX (Tesis Doctorals en Xarxa)
reponame:TDR. Tesis Doctorales en Red
instname:CBUC, CESCA
instname_str CBUC, CESCA
reponame_str TDR. Tesis Doctorales en Red
collection TDR. Tesis Doctorales en Red
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869402986160062464
spelling Optical grating coupler biosensor and biomedical applicationsDiéguez Moure, LorenaElectrònicaElectrónicaElectronicsNanotecnologiaNanotecnologíaNanotechnologyDetectors òpticsSensores ópticosOptical detectorsCiències Experimentals i Matemàtiques53Biosensors are nowadays a powerful tool to enable the detection of specific biological interactions and to evaluate the concentration dependence in the response. A biosensor usually consists of three different parts: the sample to be measured, the transducer and the electronic system that amplifies the signal, analyzes the data and brings a result to the final user. The transducer includes the bioreceptor (which specifically interacts with the sample) and the interface that transforms the recognition from the bioreceptor into a measurable signal. When the analyte interacts with the bioreceptor, the transducer sends a signal that is processed by the electronics. All this process occurs in an efficient, quick, cheap, easy, simple and specific way. Regarding the type of the transductor, the biosensors can be electrochemical, optical, acoustic, magnetic or thermometric; but overall the most powerful ones are the optical biosensors, and among them the grating coupler. As a technique for investigating processes at the solid/liquid interface, presents high mechanical stability, immunity to electromagnetic interferences and pushes the sensitivity to levels even higher than other techniques and allows for the direct monitoring of macromolecular adsorption. Taking advantage of the last advances in nanotechnology, the goal of this thesis is to study the versatility of an Optical Grating Coupler Biosensor. The design of new grating sensor chips will be investigated, a new calibration technique for the sensors will be proposed and, taking advantage of the technique, different biomedical scenarios will be tested.Esta tesis consiste en el diseño, fabricación y test de un Biosensor Óptico basado en redes de difracción y sus aplicaciones en biomedicina. Los biosensores ópticos son dispositivos que detectan interacciones biomoleculares específicas mediante un transductor óptico. Exhiben alta sensibilidad, alta estabilidad mecánica, son inmunes a las interferencias electromagnéticas y permiten medidas no destructivas. En los Biosensores Ópticos por Onda Evanescente un modo guiado se propaga a lo largo de la guía de ondas mientras que la onda evanescente interactúa con la superficie del sensor, reconociendo cualquier interacción biomolecular que provoque una modificación en el índice de refracción efectivo de la guía óptica. En este caso, la inserción de luz láser en la guía óptica se produce con ayuda de una red de difracción grabada en la superficie del sensor. Para un ángulo muy preciso se excita un modo guiado. Como consecuencia de las reacciones en la superficie se produce un cambio en el ángulo de acoplo. La medida en tiempo real del ángulo de acoplo, en función de la actividad bioquímica en la superficie es la base de este tipo de biosensor óptico. El objetivo es fabricar sensores de bajo coste en polímero y también en distintos materiales que permitan calibrar otras técnicas. Otro objetivo de esta tesis es la calibración de los sensores y de las distintas soluciones buffer comúnmente usadas en biosensado. Como aplicación, se ha usado un equipo comercial (Optical Waveguide Lightomode Spectroscopy, OWLS, MicroVacuum) para estudiar, mediante control electroquímico, el crecimiento y la liberación de multicapas de PLL/DNA para aplicaciones en administración de fármacos. También se ha usado el OWLS para optimizar la inmovilización de receptores olfativos en un dispositivo biosensor para el desarrollo de una nariz bioelectrónica.Universitat de BarcelonaMoreno Sereno, MauricioMartínez Fraiz, ElenaUniversitat de Barcelona. Departament d'Electrònica201320132012info:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/publishedVersion261 p.application/pdfapplication/pdfhttp://hdl.handle.net/10803/101149TDX (Tesis Doctorals en Xarxa)reponame:TDR. Tesis Doctorales en Redinstname:CBUC, CESCAInglésADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.info:eu-repo/semantics/openAccessoai:www.tdx.cat:10803/1011492026-06-14T12:46:07Z
score 15,301603