Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography
The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters fro...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2019 |
| País: | España |
| Institución: | Institut d'Investigació i Innovació Parc Taulí (I3PT) |
| Repositorio: | r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí |
| OAI Identifier: | oai:i3pt.fundanetsuite.com:p5212 |
| Acceso en línea: | https://i3pt.portalinvestigacion.com/publicaciones/5212 |
| Access Level: | acceso abierto |
| Palabra clave: | Non-invasive respiratory monitoring cardiorespiratory monitoring surface diaphragm electromyography wearable wireless device chronic respiratory diseases fixed sample entropy |
| id |
ES_0718979c35d2face94ff90a843e5bfc8 |
|---|---|
| oai_identifier_str |
oai:i3pt.fundanetsuite.com:p5212 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm ElectromyographyRàfols-de-Urquía, MEstrada, LEstévez-Piorno, JSarlabous, LJané, RTorres, ANon-invasive respiratory monitoringcardiorespiratory monitoringsurface diaphragm electromyographywearable wireless devicechronic respiratory diseasesfixed sample entropyThe use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters from surface diaphragm electromyography (EMGdi). Twenty healthy volunteers underwent an incremental load respiratory test whilst EMGdi was recorded with a Shimmer3 wearable device (EMGdi(W)). Simultaneously, a second EMGdi (EMGdi(L)), inspiratory mouth pressure (Pmouth) and lead-I electrocardiogram (ECG) were recorded via a standard wired laboratory acquisition system. Different cardiorespiratory parameters were extracted from both EMGdi(W) and EMGdi(L) signals: heart rate, respiratory rate, respiratory muscle activity, and mean frequency of EMGdi signals. Alongside these, similar parameters were also extracted from reference signals (Pmouth and ECG). High correlations were found between the data extracted from the EMGdi(W) and the reference signal data: heart rate (R = 0.947), respiratory rate (R = 0.940), respiratory muscle activity (R = 0.877), and mean frequency (R = 0.895). Moreover, similar increments in EMGdi(W) and EMGdi(L) activity were observed when Pmouth was raised, enabling the study of respiratory muscle activation. In summary, the Shimmer3 device is a promising and cost-effective solution for the ambulatory monitoring of respiratory muscle function in chronic respiratory diseases.IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC2019info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://i3pt.portalinvestigacion.com/publicaciones/5212IEEE Journal of Biomedical and Health InformaticsISSN: 21682194ISSNe: 21682208reponame:r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulíinstname:Institut d'Investigació i Innovació Parc Taulí (I3PT)Inglésinfo:eu-repo/semantics/openAccessoai:i3pt.fundanetsuite.com:p52122026-06-21T15:30:37Z |
| dc.title.none.fl_str_mv |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| title |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| spellingShingle |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography Ràfols-de-Urquía, M Non-invasive respiratory monitoring cardiorespiratory monitoring surface diaphragm electromyography wearable wireless device chronic respiratory diseases fixed sample entropy |
| title_short |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| title_full |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| title_fullStr |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| title_full_unstemmed |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| title_sort |
Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography |
| dc.creator.none.fl_str_mv |
Ràfols-de-Urquía, M Estrada, L Estévez-Piorno, J Sarlabous, L Jané, R Torres, A |
| author |
Ràfols-de-Urquía, M |
| author_facet |
Ràfols-de-Urquía, M Estrada, L Estévez-Piorno, J Sarlabous, L Jané, R Torres, A |
| author_role |
author |
| author2 |
Estrada, L Estévez-Piorno, J Sarlabous, L Jané, R Torres, A |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Non-invasive respiratory monitoring cardiorespiratory monitoring surface diaphragm electromyography wearable wireless device chronic respiratory diseases fixed sample entropy |
| topic |
Non-invasive respiratory monitoring cardiorespiratory monitoring surface diaphragm electromyography wearable wireless device chronic respiratory diseases fixed sample entropy |
| description |
The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters from surface diaphragm electromyography (EMGdi). Twenty healthy volunteers underwent an incremental load respiratory test whilst EMGdi was recorded with a Shimmer3 wearable device (EMGdi(W)). Simultaneously, a second EMGdi (EMGdi(L)), inspiratory mouth pressure (Pmouth) and lead-I electrocardiogram (ECG) were recorded via a standard wired laboratory acquisition system. Different cardiorespiratory parameters were extracted from both EMGdi(W) and EMGdi(L) signals: heart rate, respiratory rate, respiratory muscle activity, and mean frequency of EMGdi signals. Alongside these, similar parameters were also extracted from reference signals (Pmouth and ECG). High correlations were found between the data extracted from the EMGdi(W) and the reference signal data: heart rate (R = 0.947), respiratory rate (R = 0.940), respiratory muscle activity (R = 0.877), and mean frequency (R = 0.895). Moreover, similar increments in EMGdi(W) and EMGdi(L) activity were observed when Pmouth was raised, enabling the study of respiratory muscle activation. In summary, the Shimmer3 device is a promising and cost-effective solution for the ambulatory monitoring of respiratory muscle function in chronic respiratory diseases. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://i3pt.portalinvestigacion.com/publicaciones/5212 |
| url |
https://i3pt.portalinvestigacion.com/publicaciones/5212 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
| publisher.none.fl_str_mv |
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
| dc.source.none.fl_str_mv |
IEEE Journal of Biomedical and Health Informatics ISSN: 21682194 ISSNe: 21682208 reponame:r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí instname:Institut d'Investigació i Innovació Parc Taulí (I3PT) |
| instname_str |
Institut d'Investigació i Innovació Parc Taulí (I3PT) |
| reponame_str |
r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí |
| collection |
r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869402957851656192 |
| score |
15,198674 |